Wolf H-4DC User Manual

Page 2

Advertising
background image

‘Wolflite’ Primary Cell Safety Handlamp H-4DC
Operation and Maintenance Instructions

Certification

EEx e ib IIB T4

Certificate: BASEEFA Ex. 843292

Certificate: 86/00089

Use of ‘Wolflite’ Primary Cell Handlamps in Hazardous Areas

• The H-4DC Handlamp is approved for use in potentially explosive gases and vapours

zone 1 and 2. Applicable standards: EN 50014:1977, EN 50019:1977, EN 50020:1977.

• Copies of Certificates are available on request.

• Users should consult EN IEC 60079 for guidance on the selection, use, inspection

and maintenance of products for use in potentially explosive atmospheres, or
national equivalent.

• A damaged Lamp should be withdrawn, examined and repaired before being put back

into service.

• Maintenance and repair must only be carried out by a competent technician or electrician

familiar with Certified Electrical Apparatus, in accordance with these maintenance
instructions using factory supplied spare parts.

• Lamps must not be opened in hazardous areas. All maintenance to be carried out in

a safe area.

• Ingress Protection Level for H-4DC Handlamp: IP 66 to EN 60529:1992.

• Heavily soiled Lamps must not be immersed in water or exposed to high pressure water

jets for cleaning.

• The H-4DC Handlamp body may constitute a static hazard, clean only with a damp cloth.

• Permissible Hazardous Area ambient temperature: –20°C to +50°C.

Primary cell powered lamps are supplied without cells.

Primary Cells
Use only D size R20 zinc cells, to IEC 60086.

DO NOT MIX CELLS; DO NOT USE RECHARGEABLE CELLS