7

OPTIONAL FAN

INSTALLATION

Fan Kit Contains:

Qty. Description
1

Fan Speed Controller with nut, and knob.

1

Fan Assembly c/w green wire attached

1

power cord

1

Plastic locking grommet

1) Remove the Top Control Panel Assembly by

removing the three screws. Diagram 1.

be in the down position when control panel
is in place.

4) Push black knob onto speed control.

5) Remove the rear access panel on the back

of the stove. Remove the 3 top screws, but
only loosen the 3 bottom screws - the panel
can then be lifted off. Install the fan onto pins
as per diagram 2.

Diagram 1

Diagram 2

Hint for pushing fan down onto pins - rub
a bit of dish soap on the pins so the
grommets will slide down more easily.
Check to make sure the fan is seated
properly on the pins - try to move the fan
back and forth.

6) Push power cord through hole in the rear

panel 14" - 16" and tie a loose knot in the
cord on the inside to prevent the power
cord from being pulled out. Diagram 2.

7) Install locking grommet to power cord and

push through hole in the rear panel and give
a 1/4 turn to secure.

NOTE: When running wires, keep them

clear of valve assembly and tubing
to avoid tangling of wires and valve.

NOTE: Be careful not to cut wires when

passing through holes in the fire-
box.

8) Run green ground wire from fan and con-

nect to grounding lug.

INSTALLATION

8) Install optional Remote Control, or Wall Ther-

mostat, page 13.

9) Final check, page 14.

Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to cus-
tomer.

This includes:
1)
Clocking the appliance to ensure the cor-

rect firing rate (rate noted on label) after
burning appliance for 15 minutes.

2) If required, adjusting the primary air to

ensure that the flame does not carbon. First
allow the unit to burn for 15-20 min. to
stabilize.

CAUTION: Any alteration to the product
that causes sooting or carboning or that
results in damage is not the responsibil-
ity of the manufacturer.

CLEARANCES TO

COMBUSTIBLES

The clearances listed below are MINIMUM dis-
tances. Measure the clearance to both the
appliance and the chimney connector. (The
farthest distance is correct if the two
clearances do not coincide.)
For example,
if the appliance is set as indicated in one of the
figures but the connector is too close, move the
stove until the correct clearance to the connec-
tor is obtained.

This appliance may be installed only with the
clearances as shown in the situations pictured.
Do not combine clearances from one type of
installation with another in order to achieve
closer clearances.

Use the minimum clearances shown in the
diagrams below for installation with "B" vent.

E63-NG1 & E63-LP1 Clearances

A

Left Side Wall to Unit

6" / 150 mm

B

Right Side Wall to Unit

10" / 255 mm

C

Back Wall to Unit

5" / 125 mm

D

Vertical Vent Pipe to
Back Wall

2" / 50 mm

E

Unit Corner to Wall

2" / 50 mm

Mantel

18" / 460 mm

Unit to Alcove Ceiling

18" / 460 mm

Max. Alcove Depth

24" / 610 mm

Minimum ceiling height is 18" / 460 mm from top
of unit.

If further reduced clearances are needed,
obtain requirements for construction of a pro-
tected wall from your local building authorities
and their allowable reductions of the listed
clearances.

This unit can be installed on a solid combustible
surface like a wood floor. This unit can also be
installed directly on carpeting or vinyl when the
bottom pedestal cover plate (provided with unit)
is installed.

2) Remove the nylon hole plug from the con-

trol panel.

3) Install the fan speed controller onto the

control panel and secure with nut. Connect
remaining wire harness wires to speed
control. NOTE: Speed control wires must

Advertising