Configuration menu, Programming your thermostat – White Rodgers 775 User Manual

Page 5

Advertising
background image

www.white-rodgers.com

CONFIGURATION MENU

6

The configuration menu allows you to set certain thermostat
operating characteristics to your system or personal require-
ments.

Press RUN to make sure the thermostat is in the run program
mode, then press PRGM and RUN at the same time to enter the
configuration menu. The display will show the first item in the
configuration menu.

The configuration menu table summarizes the configuration op-
tions. An explanation of each option follows.

Press HOLD to change to the next menu item or press TIME to go
backwards to the previous item in the menu. To exit the menu and
return to the program operation, press RUN. If no keys are
pressed within fifteen minutes, the thermostat will revert to normal
operation.

1)

Select FA or SL (Fast or Slow) Heating Cycle Rate—The
FA setting is frequently used for gas, oil or electric heat. The
SL setting produces a longer heating cycle which is normally
for hot water or steam (hydronic) systems. Both settings
produce very accurate temperature control and can be set to
your personal preference. FA cycles the system just under
1

°

F and the SL setting cycles at approximately 1.5F

°

.

2)

Select backlit display—The display backlight improves
display contrast in low lighting conditions. Selecting backlight
ON will keep the light on for a short period of time after any
key is pressed. Selecting OFF will keep the light off.

3)

Select Energy Management Recovery OFF or ON
Energy Management Recovery (EMR) causes the thermo-
stat to start heating or cooling early to make the building

The only way to restore this feature is to complete a software
reset (see reset operation under “TROUBLESHOOTING”
section).

COPY DAY FUNCTION—This feature allows a selected

day’s program to be copied to the desired days’ program-
ming. To use this feature in view PRGM mode, select the day
to be copied from by pressing HOLD key. Enter the program
for the selected day as described in PROGRAMMING YOUR
THERMOSTAT. To enter the copy mode, press the TIME key
for greater than 4 seconds. The LCD should display COPY,
the selected day of the week and the day (flashing) to be
copied to. Press the HOLD key to select the day to be copied
to. Press TIME to execute copy day operation and return to
view program mode. Press RUN key to exit.

Press or to select:

SL

OFF

OFF

ON

4 LO to 4 HI

C

Configuration Menu

* Press

HOLD

to advance to next item or

TIME

to move backwards to previous item

Step

1

2

3

4

5

6

7

Press Button(s)

PRGM and RUN

HOLD*

HOLD*

HOLD*

HOLD*

HOLD*

RUN

Displayed (Factory Default)

(FA)

d-L (ON)

E (ON)

LOC (OFF)

0 HI (0)

(F)

Comments

Select FA or SL (Fast or Slow) heating cycle rate

Select display backlight OFF or ON

Select Energy Management Recovery OFF or ON

Select compressor lockout OFF or ON

Select temperature display adjustment higher or lower

Select temperature display to F or C

Returns to normal operation

temperature reach the program setpoint at the time you
specify. Heating will start 5 minutes early for every 1

°

of

temperature required to reach setpoint.

Example: You select EMR and have your heating pro-
grammed to 65

°

at night and 70

°

at 7 AM. If the building

temperature is 65

°

the difference between 65

°

and 70

°

is 5

°

.

Allowing 5 minutes per degree the thermostat setpoint will
change to 70

°

at 6:35 AM. Cooling allows more time per

degree because it takes longer to reach temperature.

4)

Select Compressor Lockout LOC OFF or ON—Selecting
LOC ON will cause the thermostat to wait 5 minutes before
turning on the compressor if the heating and cooling system
loses power. It will also wait 5 minutes minimum between
cooling cycles. This is intended to help protect the compres-
sor from short cycling. Some newer compressors already
have a time delay built in and do not require this feature. Your
compressor manufacturer can tell you if the feature is already
present in their system. When the compressor time delay

occurs it will flash the

for about five minutes then turn on

the compressor.

5)

Select Temperature Display Adjustment 4 LO to 4 HI
Allows you to adjust the room temperature display 4

°

higher

or lower. Your thermostat was accurately calibrated at the
factory but you have the option to change the display tem-
perature to match your previous thermostat.

6)

Select F

°

or C

°

Readout—Changes the display readout to

Centigrade or Fahrenheit as required.

PROGRAMMING YOUR THERMOSTAT

This section will help you plan your thermostat’s program to meet
your needs. For maximum comfort and efficiency, keep the
following guidelines in mind when planning your program.

• When heating (cooling) your building, program the tempera-

tures to be cooler (warmer) when the building is vacant or
during periods of low activity.

• During early morning hours, the need for cooling is usually

minimal.

Look at the factory preprogrammed times and temperatures shown
below. If this program will suit your needs, simply press the RUN
button to begin running the factory preset program.

If you want to change the preprogrammed times and tempera-
tures, follow these steps.

Determine the time periods and temperatures for each day
programs. You must program four periods for each day program.

7

Advertising