This is an advanced proprietary algorithm capable of determining the health of a battery. Specially stored
parameters allowing the Analyzer X3 or X6 to identify a battery’s range of capacity and display: Batt>60% or
Batt<60%of rated capacity . Batteries that have a low state of charge when placed in the X3 for the QT
May require a charge of up to 10 minutes before performing the QT. Up to 3 attempts to charge the battery

will be tried before a message is displayed “Discard the Battery”.

Even batteries that do not have pre-stored parameters can have a QT on, but will first be required to go
through the “ Learn Mode”. Note, first a good battery must be learned before QT can be performed .
A impedance test must be performed prior to the “Learn Mode”, and incorporated into the LEARN MODE.

SELECTING “ QUICK TEST “

RESULTS

SELECTING “ CONDITION “

AND RESULTS

FOR RESULTS

PUSH

QUICK TEST ANALYSIS

BATT>60% 0R BATT<60%

Display After “Turn On”

After the battery is placed
in the adapter

NO

NO

NO

NO

ACTION

ACTION

ACTION

ACTION

REMOVE BATTERY

PUSH FUNCTION BUTTON
until battery
specs appear
in the display

READY

EMPTY

TO PROCEED PRESS

<FUNCTION>

LION 1650 MAH 7.4V

<FUNCTION> FOR NEXT

LION 1650 MAH 7.4V

HAS BEEN SELECTED

HAS BEEN SELECTED

QUICK TEST

QUICK TEST

TEST

<FUNCTION> FOR NEXT

ACTION DISPLAY

QUICK TEST ANALYSIS

9

Condition Mode

The CONDITION CYCLE serves basically two needs of Nickel based batteries, one is to reform the

Cells of a battery that hasn’t been used for an extended period of time, say for 3 or more Months.

Usually deep discharging the battery will restore the battery back to normal capacity such as the discharging

and charging cycle used in the Analyzer X3 and X6.
Lithium Ion batteries do not suffer from voltage depression, but they will not be harmed if the Conditioning

cycle is applied to them. To select the condition cycle follow the instructions below.


ACTION

Display After “Turn On”

After the battery is placed
in the adapter

NO ACTION

NO ACTION

NO ACTION

NO ACTION

NO ACTION

NO ACTION

NO ACTION

FOR RESULTS

PUSH FUNCTION BUTTON
until battery
specs appear
in the display

PUSH

PUSH

PUSH

CYCLE/AUTO/CONDITION

<FUNCTION> FOR NEXT

CYCLE/AUTO/CONDITION

HAS BEEN SELECTED

CYCLE 1

CONDITION TO 80%

CONDITION TO 80%

HAS BEEN SELECTED

TESTING

READY

CONDITION - DONE 1

CAP= 85% 595 MAH

<FUNCTION> FOR NEXT

<FUNCTION> FOR NEXT

EMPTY

TO PROCEED PRESS

<FUNCTION>

NICD 700 MAH 7.2V

<FUNCTION> FOR NEXT

NICD 700 MAH 7.2V

HAS BEEN SELECTED

QUICK TEST

<FUNCTION> FOR NEXT

Secondly this mode will eliminate MEMORY EFFECT better known as VOLTAGE DEPRESSION.

With the X3 and X6, the percentage of the rated capacity of the battery being CONDITIONED is set at 80%, the 80%
is set at the factory and can be modified with the use of optional software.