I N S TA L L A T I O N

I N S T R U C T I O N S

E L E C T R I C A L

R E Q U I R E M E N T S

ELECTRICAL SHOCK HAZARD —

Plug into a grounded 3-prong adapter.

Do not remove ground prong.

Do not use an adapter.

Failure to follow these instructions can
result in electric shock, fire or death.

R E C O M M E N D E D G R O U N D M E T H O D

IMPORTANT NOTE: For your personal safety,
this cooktop must be grounded. This cooktop
is equipped with a 3-prong ground plug. To
minimize possible shock hazard, the cord must
be plugged into a mating 3-prong ground-type
outlet, grounded in conformance with all local
codes and ordinances. If a mating outlet is not
available, it is the obligation of the customer to
have a properly grounded, 3-prong outlet
installed by a qualified electrician.

IMPORTANT NOTE: If product is connected to
a GFCI protected outlet, nuisance tripping of
power supply may occur, resulting in loss of
product operation.

W I R I N G D I A G R A M

A wiring diagram covering the control circuit
for each Wolf gas cooktop model can be found
on page 17.

IMPORTANT NOTE: If codes permit and a
separate ground wire is used, it is recom-
mended that a qualified electrician determine
that the ground path is adequate.

IMPORTANT NOTE: Check with a qualified
electrician if you are not sure whether the
cooktop is properly grounded.

IMPORTANT NOTE: Do not ground to a gas
pipe.

A 220-240 V AC, 50/60 Hz, fused electrical
supply is required. A time-delay fuse or circuit
breaker is recommended. It is recommended
that a separate circuit serving only this appli-
ance be provided.

Electronic ignition systems operate within
wide voltage limits, but proper ground and
polarity are necessary. In addition to checking
that the outlet provides 220-240 V AC power
and is correctly grounded, the outlet must be
checked by a qualified electrician to see if it is
wired with correct polarity. A wiring diagram is
provided in the literature package.

This appliance, when installed, must be electri-
cally grounded in accordance with local codes.