ADDITIONAL FEATURES

In the event of automatic shut down or continuous
audible alarm, turn the inverter rocker switch to the OFF
(O) position until the source of the related problem has
been identified and resolved.

Wall Mounting:

The Pro-800W has provisions for wall mounting;
slotted holes allow for easy wall mounting of the unit.

For You Television Fans and Audiophiles.
Although the inverter is shielded and filtered to minimize
signal interference, some interference with your television
picture may be unavoidable, especially with weak signals.
However, here are some suggestions that may improve
the reception.
1. First, make certain that the television antenna pro

duces a clear signal under normal operation
conditions (i.e., at home plugged into a standard
110AC wall outlet). Also, ensure that the antenna
cable is properly shielded and of good quality

2. Change the relative positions of the inverter, antenna

cables and television power cord.

3. Isolate the television, its power cord and antenna

cables and television power cord.

4. Coil the television power cord and the input cables

running from the 12 volt power source to the inverter.

ADDITIONAL FEATURES

16

Automatic Shut Down & Related Safety Features.

Each Whistler inverter model has an unique LED Indicator

warning light system which operates in conjunction with

the automatic shut down feature. These indicator lights

operate as follows:

GREEN LED:

System ready.

RED LED:

System overload/automatic shut down.

Your inverter will shut down automatically when any of the

following problems occur:

1. The power input from the battery drops below

10 volts.

2. The power input from the battery exceeds 15.5+/-0.5

volts.

3. The continuous draw of the appliance or equipment

being operated exceeds the design parameters of the

inverter.

The inverter is equipped with the following additional safety

features:

1. Thermal Cut Off

Automatic shut down if internal temperature exceeds safe

design parameters.

2. Low Battery Voltage Alarm/Shutdown Protection

a) When the input voltage from the 12 volt power

source drops below 10.5 volts, an audible tone will

be heard. This is the low battery voltage alarm.

b) The inverter will automatically shut down when the

input voltage drops below 10 volts. This protects the
battery from completely draining.

pro800w.qxp 4/30/2010 9:00 AM Page 19