Installation, Wcp85, Continued) – Wayne WCP85 User Manual

Page 3

Advertising
background image

3

WCP85

Installation

(Continued)

furnace drain (if applicable), to the
inlet holes on the pump. Refer to
Figure 5.

STEP 4: INSTALLATION OF
DISCHARGE LINE

NOTE: Use 3/8” I.D. (max.) flexible
tubing.. A hose clamp is recommended
(not provided).

A. Extend discharge pipe from barbed

check valve to the highest point
possible. Refer to Figure 6.

B. From this point, direct the

discharge line to the location of the
drainage source. Maintain a
continuous downward slope.

NOTE: Construct an inverted “U” (see
Figure 6) at the highest point of
discharge line if a continuous
downward slope is not possible.
Exercise care not to kink or “pinch off”
the flow of condensate liquid.

STEP 5: INSTALLATION OF
SAFETY SWITCH (IF APPLICABLE)

Connect power cord
to a constant

voltage source. Do not connect to a fan
or other device that may run
intermittently.

A. The pump can be wired directly to

the appliance thermostat to shut
the pump and appliance down in
the event of pump failure. Refer to
Figure 7 for typical wiring diagram.

NOTE: The alarm can be wired in the
safety switch at the normally open
(“NO”) contact.

TIPS FOR EASY INSTALLATION

1. After reading instructions, check to

make sure installation does not
exceed a maximum of 15 feet of
vertical lift.

2. Make sure pump is level. No part of

the pump base should be more
than 1/8” off of level plane.

3. Use soapy water on unit when

performing cleaning maintenance.
(Refer to Maintenance guidelines.)

4. For optimum performance, drain

and discharge lines should have a
continuous downward slope. Test
operation of pump to make sure
lines have enough downward slope

Figure 4 - Modification of pipe end to prevent blockage

Figure 5 - Plumbing pipe from drain to inlet holes on pump

Main Drain from Coil

Overflow Drain from
Coil When Required

GFCI
Outlet

Overflow Drain
from Furnace

Condensate Neutralizer
Cartridge (If Required)

Main Drain
from Furnace

High efficiency
gas furnace

Figure 6 - Installation of discharge line

15 Ft.
Max

Inverted “U”

To Main Drain

Hose clamp

(recommended, not included)

GFCI
Outlet

Do not kink or pinch

3/8” ID Tubing