Installation manual, Maintenance, Troubleshooting – Wayne 200000-015 User Manual

Page 6

Advertising
background image

6

MAINTENANCE

ALWAYS DISCONNECT THE PUMP FROM POWER SUPPLY
before installing, servicing or making any adjustments.

LET PUMP COOL FOR A MINIMUM OF 2 HOURS BEFORE
ATTEMPTING TO SERVICE.
Submersible pumps contain oil that
become pressurized and hot under normal operating conditions.

1. Submersible pump models have permanently lubricated

bearings and require no additional lubrication.

2. The pump should be inspected 3-4 times per year for

pump movement or buildup of debris on the switch or
fl oat. Reposition pump if it has moved. Remove any
debris that could interfere with the operation of the
switch.

3. Pedestal sump pump models have open, exposed

motors. Make sure the motor does not get wet.

4. This pump may contain dielectric oil for cooling. This

oil can be harmful to the environment. Check the state
environmental laws before disposing this oil.

5. The pump motor is equipped with automatic resetting

thermal protector and may restart unexpectedly.
Protector tripping is an indication of motor overloading as
a result of operating the pump at low heads, excessively
high or low voltage, inadequate wiring, incorrect motor
conditions, or a faulty motor or pump.

TROUBLESHOOTING

Symptoms

Possible Cause(s)

Suggested Remedies

Pump will not

start or run

1. Water level too low

2. Blown fuse or tripped circuit breaker

3. Low line voltage

4. Motor

5. Switch

6. Inlet screen clogged

7. Switch obstruction

1. Water must be at the appropriate level to activate switch

2. If blown, replace with proper sized fuse or reset breaker

3a. Contact an electrician

3b. Do not use an extension cord

4. Replace pump

5. Replace with switch kit

6. Remove debris

7. Remove obstruction to ensure free motion of switch

Pump starts and

stops too often

1. Back-flow of water from discharge

pipe

2. Switch

3. Check valve not functioning

properly or leaking

1. Install check valve

2. Replace with switch kit

3. Remove and examine check valve for prop er in stal la tion and

free operation. Replace check valve if necessary.

INSTALLATION MANUAL

Printed on 100% Recycled Paper

Advertising