TROUBLESHOOTING

SCANNER PROGRAMMING BAR CODES

BEEPER INDICATIONS

Scanner not working

Check system power;
ensure power supply,
if required, is connected

No power to scanner

Ensure that correct
interface cable is used

Incorrect interface
cable used

Check for loose
cableconnections

Interface/power
cables are loose

Standard Use

Power up

Low/medium/high beep

Bar code decoded [if
decode beeper enabled]

Short high beep

Transmission error
detected; data is ignored

4 long low beeps

LED INDICATIONS

Scanner is on and
ready to scan, or no
power to scanner

Off

Bar code is
successfully decoded

Green

Transmission error

Red

Parameter Menu Scanning

Successful parameter
setting

High/low/high/low beep

Correct programming
sequence performed

High/low beep

Incorrect programming
sequence or Cancel bar
code scanned

Low/high beep

Scanner not decoding bar code

Ensure scanner is
programmed to read type
of bar code beingscanned

Scanner not programmed
for bar code type

Ensure bar code is not
defaced; try scanning
test bar code of same
bar code type

Bar code unreadable

Move scanner
closer to or further
from bar code

Distance between
scanner and bar
code incorrect

Scanner decoding bar code, but data not transmitting to host

Check scanner host parameters
or edit options

Scanner not programmed for
correct host interface

Check for loose cable connections

Interface cable is loose

Scanned data incorrectly displayed on host

Check scanner host parameters or edit options

Scanner not programmed for correct host interface

USB Host Types

Keyboard Wedge Host Types

<Enter>

<Tab>

Set Postamble

Erase All Rules

Save All Rules

Begin New Rules

Send All Data

QUICK START GUIDE

w w w . w a s p b a r c o d e . c o m

Start Here if you have a USB scanner

Enter

Choose a Postamble

Tab

Start Here if you have a keyboard wedge scanner

1

1

2

3

4

5

If you do not need a Postamble scan Erase All Rules only.

NOTE

©2005 Wasp Technologies. All rights reserved.

Wasp reserves the right to make changes to any product to improve reliability, function, or design. Wasp does not assume any product liability arising out of, or in connection with, the
application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent,
covering or relating to any combination, system, apparatus, machine, material, method, or process in which Wasp products might be used. An implied license exists only for equipment,
circuits, and subsystems contained in Wasp products. Wasp and the Wasp logo are registered trademarks of Wasp Technologies. Other product names mentioned in this manual may be
trademarks or registered trademarks of their respective companies and are hereby acknowledged.
Wasp Technologies, 1400 10th Street, Plano, TX 75074, www.waspbarcode.com

Advertising