Rolling grilles, For technical information, visit – Wayne-Dalton 600 User Manual

Page 6

Advertising
background image

Printed in U.S.A.

Item #333072 Revised 4/2008

Distributed By:

6 0 0

S E R I E S

ROLLING GRILLES

PART I – GENERAL

1.01 Work Included

A. The opening will be equipped withWayne-Dalton

600 Series rolling grilles.

1.02 Related Work

A. Opening preparation,miscellaneous or structural metal

work,access panels,finish or field painting,field

electrical wiring,wire,conduit,fuses,and disconnect

switches are in the Scope ofWork of other divisions

or trades.

1.03 Reference Standards

A. ANSI/DASMA203 –American National Standards

Institute Specifications for non-rated fire rolling doors

published by Door &Access Systems Manufacturers

Association International.

B. ASTM A123 – Zinc [hot-dipped galvanized] coat-

ings

on iron and steel products.

C. ASTM A229 – Steel wire,oil-tempered for

mechanical springs.

D. ASTM A-653-94 – Steel sheet,zinc-coated

[galvanized] by the hot-dipped process,

commercial quality.

1.04 Quality Assurance

A. Rolling grilles and all accessories and components

required for complete and secure installations shall be

manufactured as a system from one manufacturer.

1.05 Systems Description

A. Rolling Grille:Type:

Model 600

B. Mounting:[steel] [wood] [masonry] jambs

C. Operation:[manual push-up] [crank] [chain hoist]

[motor] [motor with chain hoist]

D. Material:[Galvanized steel] [aluminum] [stainless steel]

1.06 Submittals

A. Shop Drawings:Clearly indicate the following:

1. All details required for complete operation

and installation.

2. Hardware locations.

3. Type of metal and finish for door sections.

4. Finish for miscellaneous components and

accessories.

B. Product Data:Indicating manufacturer’s product

data,and installation instructions.

1.07 Delivery, Handling, Storage

A. Deliver products in manufacturer’s original containers,

dry,undamaged,seals and labels intact.

B. Store and protect products in accordance with

manufacturer’s recommendations.

1.08 Warranty

A. Standard manufacturer’s one year warranty against

defects in material and workmanship.

PART I I – PRODUCTS

2.01 Curtain

A. Curtains are to be fabricated of 5/16" galvanized

steel horizontal rods,continuous from jamb to jamb,

covered with aluminum tubes.Vertical links and tubes

available in stainless,aluminum or galvanized steel.End

links insure that grille cannot be pulled from guides.

2.02 Guides

A. Guides will be of extruded aluminum with wool pile

inserts to contact both faces of grille,acting as wearing

surfaces and sound deadener.

2.03 Brackets

A. Bracket Plates will be of 3/16” minimum [1/4”] steel

plate.Sealed ball bearings to support the

counterbalance assembly.Brackets to form end

closures and support hoods.

2.04 Counterbalance

A. Curtain to be coiled on a pipe of sufficient size to

carry door load with deflection not to exceed .033"

per foot of door span and to be correctly balanced by

helical springs,oil tempered torsion type.Cast iron

barrel plugs will be used to anchor springs to tension

shaft and pipe.

2.05 Hood

A. When required,hood is to be fabricated of 24-gauge

galvanized steel (stainless steel) (20 B&S gauge

aluminum).Provide intermediate hood supports over

16'0" opening width.

2.06 Finish

Finish for aluminum surfaces is to be (mill) (clear

anodized 204R1)(bronze anodized).Non-galvanized

steel surfaces are to be painted one shop coat of rust

inhibiting primer.Stainless steel to be #304 brushed.

2.07 Operation

A. Grilles will be operated by means of (manual,with lift

handles) (by chain and gear–maximum pull of 35 lbs.)

(by fully enclosed awning type crank gearing and

removable crank arm) (by motor operator).

2.08 Locking

A. Manual or crank operated grilles to be by means of

slide bolt locking device operable from inside or

outside.Chain lock keeper on chain operated doors.

Motor operated grilles to include self-locking gearing

plus chain locking device for emergency chain.

Note: When specifying locks on electric-motor operated

doors,electric interlocks should also be specified to

prevent operation when lock bolts are engaged in the

guides,thus preventing damage to the curtain

and/or operator.

PART III – EXECUTION

3.01 Installation

A. General:

1. Install grilles in accordance with manufacturer’s

instructions and standards.Installation shall be by an

authorizedWayne-Dalton representative.

2. Verify that existing conditions are ready to receive

rolling grille work.

3. Beginning of rolling grille work means acceptance

of existing conditions.

B. Install grille complete with necessary hardware,jamb

and head mold strips,anchors,inserts,hangers,and

equipment supports in accordance with final shop

drawings,manufacturer’s instructions,and as specified

herein.

C. Fit,align and adjust rolling grille assemblies level and

plumb for smooth operation.

D. Upon completion of final installation,lubricate,test and

adjust grilles to operate easily,free from warp,twist or

distortion and fitting for entire perimeter.

Note: Architect may consider providing a schedule when

more than one rolling grille or opening type is

required.

Because of continuing product improvements, we reserve the right to change the product specifications and designs without prior notice.

© 2008 Wayne-Dalton Corp. • One Door Drive • Mt. Hope, Ohio 44660 • 800-255-3046

Mt. Hope, OH • Dalton, OH • Trail, OH • Pensacola, FL • Portland, OR

For technical information, visit:

www.

wayne-dalton

.com/commercial

Note to specifiers: Words in brackets indicate frequently specified and highly recommended options.

Advertising