Caution, Warning, Figure 3. subbase – White Rodgers 1F94-80 User Manual

Page 4

Advertising
background image

4

2.

Connect wires beneath terminal screws on sub-
base using appropriate wiring schematic (see figs.
3 through 6).

3.

Place subbase over hole in wall and mark mounting
hole locations on wall using subbase as a template.

4.

Move subbase out of the way. Drill mounting holes.

5.

Fasten subbase loosely to wall, as shown in fig. 3,
using two mounting screws. Place a level against
bottom of subbase, adjust until level, and then tighten
screws. (Leveling is for appearance only and will not
affect thermostat operation.) If you are using existing
mounting holes, or if holes drilled are too large and do
not allow you to tighten subbase snugly, use plastic
expansion plugs to secure subbase.

6.

Push excess wire into wall and plug hole with a fire-
resistant material (such as fiberglass insulation) to
prevent drafts from affecting thermostat operation.

S1 S2 S3

Mounting

hole

Pull wires through

this opening

Connect wires under

terminal screws

Mounting

hole

4-pin connector

9-pin connector

O

B

Y1
Y2

C
G

W1

R

W2

Expansion

plugs

Figure 3. Subbase

E1
E2

L

A1

DO NOT EXCEED MAXIMUM VOLTAGE OR
CURRENT RATINGS. FIRE, PERSONAL IN-
JURY, AND/OR EQUIPMENT DAMAGE COULD

RESULT.
To prevent electrical shock and/or equipment
damage, disconnect electrical power at the main
fuse box until installation is complete. Verify

CAUTION

!

WARNING

!

NOTE

power is off with a voltmeter.

The following wiring diagram shows typical terminal iden-
tification and wiring. For proper installation, refer to the
original manufacturers' instructions.

L

C

R

B

O

Changeover

Energized

In Heat

Changeover

Energized

In Cool

Compressor

Contactor

Stage 1

Fan

Relay

Heat

Relay

Stage 1

Damper

Motor

Thermostat

Control

Circuit

Compressor

Contactor

Stage 2

24vAC

120vAC

Hot

Neutral

THERMOSTAT

SYSTEM

Y1

Y2

W1

A1

E1

Emergency

Relay

Constant

Output

E2

Emergency

Relay

Switched

Output

TRANSFORMER

Malfunction

Light

System

Monitor

Switch

Figure 4. Typical wiring diagram for single transformer systems

G

Heat

Relay

Stage 2

W2