Service manual – tea brewer – Wibur Curtis Company PTT3 User Manual

Page 3

Advertising
background image

PROGRAM MENUS CONTINUED

3

Continued on Page 4

Service Manual – Tea Brewer

Tea Dilution Stir (Factory set to ON).

Press  to Select. Press < or > buttons, to view selections available: Standard Gray, Standard Purple, Tropical Gray,

tropical Purple, 76/308 Gray or 76/308 Purple. Press  to set. Dilution Stir applies only to the Dilution cycle, by pulsing

the dilution time 45 seconds on, 5 seconds off.

Tea Pulse Brew (Factory set to OFF).

Press  to Select. Press < or > to toggle between OFF and ON.

Tea Half Batch (Factory set to OFF).

Press  to Select. Press < or > to toggle between OFF and ON. When ON, Half Batch Brew Button is activated.

Sweetener Time is only for tea brewers with the optional tea sweetening system (Factory set to 4 min, 5 sec.)

Press  to Select. Press < or > to toggle between minutes, seconds or exit. Pressing select  to choose minutes will

increase the minutes. Press  to add minutes. Press < or > to move to seconds or exit.

Temperature (Factory set to Standard Gray & Purple)

Press  to Select. Press < or > to choose Standard Gray and Purple 204ºF and then  to set. Tropical Gray and

Purple and 76/308 Gray & Purple 196ºF are the other selections. Temperature range, from 170ºF to 208ºF in 2‑degree

increments.

Energy Save Mode (Factory set to OFF)

Press  to Select, < or > ON, OFF or ON 140ºF ,  to set. When in ON, unit will automatically shut off 4 hours from

last brew. When feature is OFF, unit does not have the energy saving mode.

In the ON 140ºF position, temperature goes down to 140ºF. if unit has not brewed in 4 hours. This feature will save

energy by maintaining a lower temperature in the tank during periods of non‑operation.

Brew Count Odom.

Press  to display total brew cycles. Press ex or Reset Brew Count Total

Press  to Select, Shows total gallons and total brew cycles on the unit. Not resettable.

Brew Count Total

Press  to Select, Shows total gallons and total brew cycles on the unit. Not resettable.

Cold Brew Lock . . . (Factory set to 5º F)

Press  to select, < or > to select desired setting (CBL 5, 15 or OFF), to set.

The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point.

The first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of

set point for the Ready to Brew message, however it will brew at any temperature.

Master Reset

Press  to display Are You Sure? Then < for Yes, > for No. When Master Reset is used, the all of the menu selctions

in the UCM return to factory defaults.

Service Call (Phone number Factory set to [800] 995‑0417)

Press  to display number and change number or < to move place and EX to exit when complete. This number will

be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.

Access Code (Factory set to 1‑2‑3‑4)

Press  to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit

when complete.

Temperature

Tea Dilut Stir

Energy Save Mode

Brew Count Odom

Master Reset

Service Call

Brew Count Total

Cold Brew Lock

Tea Pulse Brew

Tea Half Batch

Sweetener Time

Access Code