Service manual – tea brewer – Wibur Curtis Company PTT3 User Manual
Page 3
PROGRAM MENUS CONTINUED
3
Continued on Page 4
Service Manual – Tea Brewer
Tea Dilution Stir (Factory set to ON).
Press to Select. Press < or > buttons, to view selections available: Standard Gray, Standard Purple, Tropical Gray,
tropical Purple, 76/308 Gray or 76/308 Purple. Press to set. Dilution Stir applies only to the Dilution cycle, by pulsing
the dilution time 45 seconds on, 5 seconds off.
Tea Pulse Brew (Factory set to OFF).
Press to Select. Press < or > to toggle between OFF and ON.
Tea Half Batch (Factory set to OFF).
Press to Select. Press < or > to toggle between OFF and ON. When ON, Half Batch Brew Button is activated.
Sweetener Time is only for tea brewers with the optional tea sweetening system (Factory set to 4 min, 5 sec.)
Press to Select. Press < or > to toggle between minutes, seconds or exit. Pressing select to choose minutes will
increase the minutes. Press to add minutes. Press < or > to move to seconds or exit.
Temperature (Factory set to Standard Gray & Purple)
Press to Select. Press < or > to choose Standard Gray and Purple 204ºF and then to set. Tropical Gray and
Purple and 76/308 Gray & Purple 196ºF are the other selections. Temperature range, from 170ºF to 208ºF in 2‑degree
increments.
Energy Save Mode (Factory set to OFF)
Press to Select, < or > ON, OFF or ON 140ºF , to set. When in ON, unit will automatically shut off 4 hours from
last brew. When feature is OFF, unit does not have the energy saving mode.
In the ON 140ºF position, temperature goes down to 140ºF. if unit has not brewed in 4 hours. This feature will save
energy by maintaining a lower temperature in the tank during periods of non‑operation.
Brew Count Odom.
Press to display total brew cycles. Press ex or Reset Brew Count Total
Press to Select, Shows total gallons and total brew cycles on the unit. Not resettable.
Brew Count Total
Press to Select, Shows total gallons and total brew cycles on the unit. Not resettable.
Cold Brew Lock . . . (Factory set to 5º F)
Press to select, < or > to select desired setting (CBL 5, 15 or OFF), to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point.
The first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of
set point for the Ready to Brew message, however it will brew at any temperature.
Master Reset
Press to display Are You Sure? Then < for Yes, > for No. When Master Reset is used, the all of the menu selctions
in the UCM return to factory defaults.
Service Call (Phone number Factory set to [800] 995‑0417)
Press to display number and change number or < to move place and EX to exit when complete. This number will
be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1‑2‑3‑4)
Press to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit
when complete.
Temperature
Tea Dilut Stir
Energy Save Mode
Brew Count Odom
Master Reset
Service Call
Brew Count Total
Cold Brew Lock
Tea Pulse Brew
Tea Half Batch
Sweetener Time
Access Code