Installation

NEXERA
The DPS850 can be configured as an integral part of the Nexera fixture. In this
configuration the DPS850 dimmed output is hard wired to the Nexera lamp
assembly eliminating the lamp connection as a potential point of failure. The
DPS850 can either be hung from pipe near the Nexera fixture or bolted to the
Nexera yoke.

Connect the DPS850 to a grounded power circuit 100 – 240VAC ~

50/60Hz.

Connect the four pin XLR accessory output to the Nexera color module

Power/Signal input. The DPS850 provides power and passes DMX and
RDM signals through to the color module.

If used, connect DMX / RDM signal to the DPS850 five pin XLR connector

labled “DMX IN”. DMX may be passed through the DPS850 to other
devices by using the connector labeled “DMX OUT”.

CONVENTIONAL LUMINAIRE
The DPS850 may be configured to be used with any luminaire up to 800 watts.
A female power connector can be installed on the dimmed output cord to match
the connector used on the luminaire. The DPS850 can be mounted to the yoke
of many theatrical fixtures or hung from mounting pipe near the associated
fixture.

Connect the DPS850 to a grounded power circuit 100 – 240VAC ~

50/60Hz.

Connect the four pin XLR accessory output to the Forerunner, CXI IT,

ColoramIT, or other theatrical accessory in use with the fixture.

Connect DMX / RDM signal to the DPS850 five pin XLR connector labeled

“DMX IN”. DMX may be passed through the DPS850 to other devices by
using the “DMX OUT” connector.