Burner data

Table 1

Boiler

Model

Number

Burner

Input

Gas

Mbh

Burner

Model

Number

Beckett

Burner

Part Number
For Ordering

Approximate

Starting

Air Settings

Starting

Head

Setting

Positive

Pressure In

Firebox

Inches W.C.

Burner

Motor

3450 Rpm

H.P.

Pressure

Drop

Through

Gas Train

Inches W.C.

Gas

Manifold
Pressure

(High

Fire)

Inches

W.C.

Gas Pressure

Required At

Gas Controls

Inlet

Inches W.C.*

Low

Fire

High

Fire

Min

Max

488R

996

CG10

CG106152

N/A

10/3.5

6

0.50

1/3

2.46

4.30

6.71

14.00

488

1010

CG10

CG106152

N/A

10/3.5

6

0.50

1/3

2.53

4.50

6.71

14.00

588

1357

CG25

CG251258

23

39

1

0.60

3/4

1.90

3.55

5.50

14.00

688

1703

CG25

CG252259

25

48

2

0.70

3/4

2.45

3.70

6.57

14.00

788

2049

CG50

CG501289

14

28

1

0.60

2

2.14

3.10

5.11

14.00

888

2396

CG50

CG502290

14

31

2

0.65

2

2.57

3.05

5.62

14.00

988R

2482

CG50

CG502291

14

34

2

0.60

2

2.44

3.10

5.50

14.00

988

2713

CG50

CG502291

14

34

2

0.60

2

2.92

3.75

5.50

14.00

1088R

2887

CG50

CG503292

17

38

3

0.65

2

1.94

3.00

6.00

14.00

1088

3103

CG50

CG503292

17

38

3

0.65

2

2.25

3.65

6.00

14.00

1188

3392

CG50

CG504293

20

50

4

0.70

2

2.65

3.60

6.45

14.00

1288

3753

CG50

CG504294

19

68

4

0.65

2

3.25

4.15

6.36

14.00

1388

4113

CG50

CG505295

24

93

5

0.70

2

2.53

4.00

6.68

14.00

*Gas pressures shown are for standard gas train arrangement. Contact Weil-McLain for alternate gas trains to support other gas pressures.