Warning, Location requirements, Electrical requirements – Whirlpool ACE082XP1 User Manual

Page 4

Advertising
background image

4

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Check the location where air conditioner will be installed. Proper
installation is your responsibility. Make sure you have everything
necessary for correct installation.

The location should provide:

Grounded electrical outlet within 4 ft (122 cm) of where the
power cord exits the air conditioner.

NOTE: Do not use an extension cord.

Free movement of air to rooms to be cooled.

A large enough opening for the air conditioner.

Adequate wall support for weight of air conditioner. Air
conditioner weighs between 80 and 110 lb (36.3 to 49.9 kg).

NOTE: Cabinet louvers must not be obstructed. Air must be able
to pass freely through the cabinet louvers.

Window installation (on some models)

Window opening measurements:

Width: 28" (71.1 cm) minimum to 40" (101.6 cm) maximum.

Height: 16

¹⁄₄" (41.3 cm) minimum.

Through-the-wall installation

The wall opening measurements should be:

Height: 16" (40.6 cm) plus twice the thickness of wood used
to build frame.

Width: 22

⁵⁄₈" (57.5 cm) plus twice the thickness of wood used

to build frame.

Electrical Requirements

Ground wire must be connected to ground screw located in lower
right corner of air conditioner when air conditioner is in cabinet.

The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located behind the front panel on the front flange above
the coil area.

Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.

A. Cabinet louvers

A. 28" (71.1 cm) minimum to 40" (101.6 cm) maximum
B. 16

¹⁄₄

" (41.3 cm) minimum

A

A

B

A. 16" (40.6 cm) + 2 x C
B. 22

⁵⁄₈

" (57.5 cm) + 2 x C

Power supply cord
plug outlet

Wiring requirements

115 volt (103.5 min. -
126.5 max.)

0-12 amps

15-amp time-delay fuse or
circuit breaker

Use on single outlet circuit only.

B

C

C

A

WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Failure to follow these instructions can result in
death, fire, or electrical shock.

Do not use an extension cord.

Do not use an adapter.

Do not remove ground prong.

Advertising