Wolf Appliance Company ICBIG15/S User Manual

Page 9

Advertising
background image

9

E L E C T R I C A L

R E Q U I R E M E N T S

Required Power Supply
220–240 V AC, 50–60 Hz, 15 amp service

Maximum Connected Load
2.8 kW

The Wolf electric grill module requires 15 amp
service with its own circuit breaker or fuse.
Locate electrical within the shaded area shown
in the illustration on page 7. A properly rated
cord should be attached to the power supply
box of the grill as shown in the illustration
below. Open the power box to expose the
screws with corresponding numbers. Loosen
the 1, 5, and ground screws. Run the cord
through the circular hole and into the power
supply box. Attach the Neutral wire to the
number 1 position. Attach the line wire to the 5
position and attach the ground wire to the
corresponding ground screw. After tightening
the screws, close the cover to the power
supply box without pinching any of the wires.

You must follow all local codes and ordinances
when installing your service.

Attach the power cord to the unit before
plugging the cord into the wall.

IMPORTANT NOTE: The correct voltage,
frequency and amperage must be supplied to
the appliance from a dedicated, grounded
circuit which is protected by a properly sized
circuit breaker or time delay fuse. The proper
voltage, frequency, and amperage ratings are
listed on the product rating plate located on
the underside of the module. Refer to the illus-
tration on page 5. The wiring diagram covering
the control circuit is located inside the module
control box.

The complete appliance must be properly
grounded at all times when electrical
power is applied.

Improper connection can result in a fire
hazard!

W O L F

G R I L L M O D U L E

Power supply box

IMPORTANT NOTE: To avoid electrical shock
when disconnecting the grill module, all
poles/wires must be disconnected from the
power supply box.

Advertising