Owner’s manual, Wiring diagrams, Replacement parts technical service service hints – Williams 4003532 User Manual

Page 19: When gas pressure is too low, When gas quality is bad

Advertising
background image

19

201842

OWNER’S MANUAL

1

2

3

4

5

6

7

Junction

Box

Black

Green

White

Black

White

White

Black

Transformer

White

Brown

Brown

Black

Motor

Green

370 V.A.C.

Capacitor

5 MFD

Terminal Block

Black

Thermostat

White

Red

Black

Yellow

Blue

Brown

Green

Black

Brown

White

Ignition
Control

Board

Probe

Black

White

White

Glo-Bar

Gas Valve

Time Delay

Relay

Limit

Switch

Sail Switch



White

115 V.A.C.

(Open)

Brown

Brown

Orange

White

White

Red

Note:

1

2

3

4

5

6

7

Junction

Box

Black

Green

White

Black

Red

White

Black

Transformer

White

Brown

Brown

Black

Brown

Motor

Green

370 V.A.C.

Capacitor

5 MFD

Yellow

Terminal Block

Black

Thermostat

White

Red

Black

Yellow

Blue

Yellow

Brown

Green

Black

Brown

Orange

White

Ignition
Control

Board

Probe

Black

White

White

Glo-Bar

Gas Valve

Time Delay

Relay

Limit

Switch

Sail Switch

Note:


White

115 V.A.C.

White

(Open)

WIRING DIAGRAMS

Figure 21 - Wiring Diagram (40,000 BTU/Hr Model)

Figure 20 - Wiring Diagram (25,000 BTU/Hr Model)

Note:

Use only original replacement parts.

This will protect your warranty coverage for
parts replaced under warranty.

All parts listed herein may be ordered from
your equipment supplier.

When ordering repair parts, always give the
following information:

• model number of your furnace

• type of gas, natural or propane/LP
• the replacement part number and de-

scription

REPLACEMENT
PARTS

TECHNICAL
SERVICE

SERVICE HINTS

When Gas Pressure Is Too Low

• glo-bar glows, but burner will not ignite

When Gas Quality Is Bad

• burner will not stay lit

• burner will produce flames and soot

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
gas supplier.

You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact your installer, a qualified service
person, or Williams Technical Help Line at
1-800-266-0993.

Advertising