Whirlpool 1997 "E" User Manual

Page 10

Advertising
background image

1-2

The normally-closed (N.C.) contacts of relay 4 provide a potential circuit for the Base Thermal
Fuse. If the base of the oven exceeds 133˚F, the thermal fuse contacts close, and a circuit for
the low-speed side of the blower motor is completed, which turns the motor on. The low-speed
blower will operate until the base temperature drops below 104˚F and opens the thermal fuse
contacts, and turns off.

N

L1

20A LINE

FUSE

CAVITY

THERMAL

FUSE

MAGNETRON

THERMAL

FUSE

BK

BK

BK

RELAY 4

BASE

THERMAL

FUSE

W

BL

YL

LOW-VOLTAGE

TRANSFORMER

W

BLOWER

MOTOR

RD

MICROCOMPUTER

BOARD

3

1

11

CAPACITOR

RD

RD

(C)

(HIGH)

When the low-speed fan is selected by the user at the control panel, relay 3 and the normally-
closed (N.C.) contacts of relay 4, complete the circuit to the low-speed windings of the blower
motor and turn it on.

N

L1

20A LINE

FUSE

CAVITY

THERMAL

USE

MAGNETRON

THERMAL

FUSE

BK

RD

BK

RELAY 4

W

BL

PK/W

LOW-VOLTAGE

TRANSFORMER

BLOWER MOTOR

RD

RELAY 3

MICROCOMPUTER

BOARD

3

1

9

CAPACITOR

RD

RD

(LOW)

(C)

When the high-speed fan is selected by the user at the control panel, the normally-open (N.O.)
contacts of relay 4 complete the circuit to the high-speed windings of the blower motor and turn
it on.

N

L1

20A LINE

FUSE

CAVITY

THERMAL

FUSE

MAGNETRON

THERMAL

FUSE

BK

RD

BK

RELAY 4

W

BL

BK

LOW-VOLTAGE

TRANSFORMER

BLOWER MOTOR

RD

MICROCOMPUTER

BOARD

3

1

13

CAPACITOR

RD

RD

(HI)

(C)