Pro low-profile wall ventilation hood, Planning information – Wolf PW422210 (R) User Manual

Page 6

Advertising
background image

6

Dimensions in parentheses are in
millimeters unless otherwise specified.

Planning Information

Pro Low-Profile Wall Ventilation Hood

M O D E L P W 4 2 2 2 1 0 ( R )

Ducting for Pro
low-profile wall hoods.

DUCTWORK INSTALLATION

THROUGH ROOF

22"

(559)

DEPTH OF HOOD

10"

(254) ROUND DUCT

SOFFIT OR CABINET

OR DUCT COVER

VERTICAL DISCHARGE

17

3

/

4

"W x 4

1

/

4

"D TO 10"

ROUND

9

3

/

8

"H (INCLUDING FLANGES)

ACCESSORY TRANSITION

FOR IN-LINE OR

REMOTE BLOWER

30"

TO

36"

(762–914)

COUNTERTOP

TO BOTTOM OF

VENTILATION HOOD

36"

(914)

STANDARD

FLOOR TO

COUNTERTOP

HEIGHT

10"

(254)

HEIGHT OF HOOD

WALL HOOD

ROOF CAP OR REMOTE BLOWER

NOTE: 10" (254) ROUND ACCESSORY TRANSITION SHOWN IN VERTICAL DISCHARGE APPLICATION WITH
IN-LINE OR REMOTE BLOWER. REFER TO INSTALLATION INSTRUCTIONS FOR HORIZONTAL DISHCARGE.

D U C T I N G C O N S I D E R A T I O N S

Wolf Pro low-profile wall hoods are shipped

without the blower assembly. Internal, in-line

and remote blower assemblies are available.

IMPORTANT NOTE: Install this ventilation hood
only with a Wolf blower.

Pro low-profile wall hoods come standard with

a horizontal or vertical discharge. No transition is

included. When using an in-line or external

blower, use the optional accessory 10" (254)

round transition.

The hood will operate most efficiently when

ductwork does not exceed 50' (15 m) in length.

Local building codes may require the use of

make-up air. Consult your local HVAC profes-

sional for specific requirements in your area.

IMPORTANT NOTE: Wolf Pro low-profile wall

hoods must be vented to the outside. Use only

metal ductwork.

Refer to the illustration below for ducting

considerations for Pro low-profile wall hoods.