Whirlpool GJD3044R User Manual

Electric built-in ceramic downdraft cooktop

Advertising
background image

21-5/16"

(54.1 cm)

depth

15-5/8" (39.6 cm)

blower housing

depth

3-ft. (91.4 cm) long

power supply cable

factory installed.

2-15/16"

(74.6 mm)
burner box

depth

30-3/8" (77.1 cm) - 30" (76.2 cm) models
36-3/8" (92.3 cm) - 36" (91.4 cm) models

width

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Electric Built-in Ceramic Downdraft Cooktop

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

CABINET OPENING DIMENSIONS

GJD3044R

Electrical: A four-wire or three-wire, single-
phase, 240-volt, 60-Hz, AC-only electrical supply is
required on a separate 30-ampere circuit, fused on
both sides of the line. A time-delay fuse or circuit
breaker is recommended. Connected directly to the
fused disconnect (or circuit breaker box) through
flexible, armored or non-metallic sheathed, copper
cable (with ground wire). Flexible armored cable
should connect cooktop directly to the junction
box. A U.L.-listed 1/2" (12.7 mm) conduit
connector must be provided at the junction box.
The recommended minimum copper wire size is
10-gauge. However, wire sizes and connections
must conform to the requirements of the National
Electrical Code and all local codes and ordinances.

Venting system: Use metal vent only.
Exception: Under a concrete slab, PVC may be
used. Rigid metal vent is recommended. Do not
use plastic or metal foil vent.

This downdraft cooktop is rated at 60 feet
(18.3 m) of straight vent or the equivalent.

If vent length is 10 feet (3 m) or less, 6" (15.2 cm)
diameter round vent may be used. If vent length is
more than 10 feet (3 m), use 6" (15.2 cm)
diameter round or 3-1/4" x 10" (8.3 x 25.4 cm)
rectangular vent.

Venting system must terminate to the outside.

Cooktop location should be away from strong draft
areas, such as windows, doors and strong heating
vents or fans.

All openings in the wall or floor where cooktop is
to be installed must be sealed.

Minimum base cabinet
dimensions —

30" (76.2 cm) base cabinet width
24" (61 cm) base cabinet depth
25" (63.5 cm) countertop depth

Countertop opening dimensions that
are shown must be used. Given
dimensions are minimum clearances
and provide required 0" (0 cm)
clearance.

New installations — Follow
minimum dimensions given.

Replacement installation — Be sure
that front edge of cooktop is at least
1-1/2" (38.1 mm) back from front
edge of countertop.

If cabinet has drawers, drawers will
need to be removed and drawer
fronts installed on front of cabinet.

Side clearance — 6" (15.2 cm)
minimum clearance between side of
cooktop and side wall is
recommended for maximum
ventilation performance.

Rear clearance — 3/4" (19.1 mm)
clearance between rear edge of
cooktop and rear wall is
recommended.

Motor/blower clearance —
2" (51 mm) minimum clearance
between motor and cabinet is
required for proper cooling. 6"
(15.2 cm) clearance is
recommended for servicing access.

17"

(43.2 cm)

9-5/8" (24.4 cm) -

30" (76.2 cm) cooktop

13-5/16" (33.8 cm) -

36" (91.4 cm) cooktop

9-3/4" (24.8 cm)

hole in rear or

side of cabinet

Exhaust Duct
Cutout Locations

Ref. 8286553

08-11-05

®

21" (53.3 cm)
opening depth

See Note ** for

minimum clearances

Do Not seal
cooktop to countertop.

Minimum distance
to nearest combustible
vertical surface
extending 18" (45.7 cm)
above cooktop

29-1/2" (74.9 cm) - 30" (76.2 cm) model
35-1/2" (90.2 cm) - 36" (91.4 cm) model

cutout width

30" (76.2 cm) min - 30" (76.2 cm) model

36" (91.4 cm) min - 36" (91.4 cm) model

when higher than 18" (45.7 cm)

1" (25.4 mm)

Install rear wall junction box in shaded area.
Darker area is preferred.

5" (12.7 cm)

18"

(45.7 cm)

11" (27.9 cm)

8" (20.3 cm)

countertop

floor

2" (5.1 cm)
minimum space
to front edge of
countertop

Select required duct cutout
(see Page 4 for exhaust duct
cutout location).

Countertop must be
supported within
3" (7.6 cm) of cutout.

21" (53.3 cm)

cutout depth

29-1/2" (74.9 cm) - 30" (76.2 cm) model
35-1/2" (90.2 cm) - 36" (91.4 cm) model

cutout width

Note: 24" (61 cm) minimum when bottom of wood or metal
cabinet is protected by not less than 1/4" (6.4 mm) flame
retardant millboard covered with not less than No. 28 MSG sheet
steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum
or 0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance between the top of the cooking
platform and bottom of unprotected wood or sheet metal.

**