INSTALLATION (continued)

9

DANGER

BURN HAZARD
HOT OIL SPILL

Any additional remote pull
station must not be installed on
the front or sides of the fryer
forward of the ventilator side
panels.
Discharge of the fire
extinguishing system into hot
oil will cause hot foam to spill
over from the frypot.
Serious burns and other
injuries can result from contact
with hot oil and from slipping in
spilled oil.

Exclusive Anti-Fire System
In the unlikely event that both
the temperature control
thermostat and hi-limit detector
fail, and the oil temperature
climbs above the safety limit,
the fire suppression system will
discharge, cooling the oil below
the oil’s (approximately) 540ºF
auto-ignition temperature, and
preventing a fire from
occurring.

BACK, HORIZ.,

RIGHT SIDE

INSTALL (5-3/4”)

BACK, HORIZ.,

LEFT SIDE,

INSTALL (8-1/4”)

MANUAL PULL

STATION PIPING

INSTALL ON LEFT

SIDE OF HOOD

INSTALL ON RIGHT

SIDE OF HOOD

OR

SIDE, VERT. (6”)

SIDE, HORIZ.

(13-1/2”)

CENTER,
VERT. 3”

INSIDE OF HOOD

LOOKING UP

IMPORTANT!

VACUUM FITTING

DO NOT INSTALL

DISCHARGE NOZZLE

HERE!

280ºF
FUSIBLE LINK

DISCHARGE

NOZZLES

FRYPOT

FUSIBLE LINK

NOTE
CABLE
ROUTED
UNDER
GUIDE

CRIMP
FERRULE

450ºF
FUSIBLE
LINK

HEATSINK

CLIP

M3

8

1

301603

O

p

M

(

S

up

p

lem

en

ta

l)

N

F

P

A

H

o

o

d