INSTALLER/CONFIGURATION MENU

Press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to advance to the
next menu item. Press

or

to change a menu item. Shaded items are not available on 1F86.

1. Select Reversing Valve Output (SS/HP switch must

be set at HP, omitted if SS/HP switch is SS Position)
– The O/B option is factory set at "O" position. This will
accommodate the majority of heat pump applications,
which require the changeover relay to be energized in
FRIO. If the thermostat you are replacing or the heat pump
being installed with this thermostat requires a "B" terminal,
to energize the changeover relay in CALOR, the O/B
option should be set at "B" position.

2. Program Options 1F80 only – This control can be

confi gured for 5/2 day or 5/1/1 day programming or non-
programming mode. The default setting is P2, indicating
5/2 day programming. The programs per week can be
toggled to P3 or P0 by pressing the

or

keys. A

selection of 0 Days for non-programmable will eliminate
the need for EMR, and that step in the menu will be
skipped.

3. Select Frio Ahorro (Cool Savings™) and value

– Selects the Frio Ahorro feature On or OFF. If selected
On, press MENU to select the amount of adjustment
for the feature in Frio mode with 1 (1°) being the least
amount of adjustment and 6 (6°) being the most amount

of adjustment. Default value is 3 (3°). In normal operation
"Ahorro" will appear under "Vent"

Cool Savings is an optional energy saving feature that
can reduce your cooling costs. It is based on the principal
that lower indoor humidity makes a slightly higher
temperature feel more comfortable. Frio Ahorro operates
during periods of high demand which normally occur
on the hottest summer days when the cooling system
may run for hours to reach the thermostat setting. Long
cooling run times also lower the indoor humidity. Frio
Ahorro
very slowly adjusts the setpoint temperature to
make the setpoint closer to the displayed temperature, to
a maximum number of degrees selected. Adjusting the
setpoint temperature over a long cooling run time allows
the system to reach your set temperature and turn off.
The room temperature will actually be higher than the
thermostat displays, but the reduction in humidity will allow
comfort at the slightly higher temperature. When Frio
Ahorro
is making adjustments, "Save" will show next to
the setpoint temperature and the room temperature may
vary within the adjustment range selected.

If this feature is selected OFF, no change will occur when
the cooling system is continually running during periods of
high demand.

INSTALLER/CONFIGURATION MENU

MENU

REF

HP

SS

PRESS

BUTTON

DISPLAYED

(FACTORY DEFAULT)

Press

or

to

select from listed options

COMMENTS

1

1

MENU

On (Frio O)

Calor b On

Reversing Valve Output (SS/HP switch must

be in the Heat Pump HP position)

2

2

1

MENU

P (2)

P 3, P 0

Selectable Programs Per Week

(For programmable thermostat only)

3

3

2

MENU

Frio Ahorra CE

(OFF)

Frio Ahorra CE On

Select Frio Ahorra (Cool Savings) on or off

MENU

Frio Ahorra (3)

6, 5, 4, 2, 1

Selects Frio Ahorra value 1 (low) to 6 (high)

4

4

3

MENU

E (On)

E OFF

Selects Energy Management Recovery (EMR)

on or off

5

4

MENU

CR Calor

(ME)

AL, bA

Adjustable Anticipation (Calor) (only when

SS/HP switch is at the SS position)

6

5

MENU

CR Frio

(AL)

bA

Adjustable Anticipation (Frio) (only when

SS/HP switch is at the SS position)

7

5

MENU

CR Bomba de Calor

(AL)

bA

Adjustable Anticipation (Bomba de Calor)

(only when SS/HP switch is at the HP position)

8

6

6

MENU

Cd (OFF)

Cd On

Compressor Lockout Time

9

7

7

MENU

Auto Calor

Frio Off

Calor Frio Off,

Calor Off with Vent icon,
Calor Off without Vent

icon, Frio Off,

Auto Off

System Mode Confi guration

with Automatic Changeover

10

8

8

MENU

L (On)

L OFF

Selects Display Light on or off

11

9

9

MENU

0

1 AL, 2 AL, 3 AL, 4

AL,

1 bA, 2 bA, 3 bA, 4 bA

Adjustable Ambient Temperature Display

12

10

10

MENU

F

C

Selects Fahrenheit/Celsius Temperature

Display

13

11

11

MENU

Cambiar Filtro (OFF)

Cambiar Filtro On

Selects Filter Change-out Indicator

MENU

Cambiar Filtro 200 h

25 h to 1975 h in

25-hour increment

When on, selects time in 25 hour increments

14

12

12

Arrancar

Returns to Normal Operation

Advertising