21

This oven must be installed by qualified
personnel
to the relevant British Standards.

Electrical Connection

Installation

The oven is designed to be connected to 240V (50Hz)
electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

or E

-

Earth terminal

THIS OVEN MUST BE EARTHED

The cable used to connect the oven to the electrical
supply must comply to the specifications given
below.

It is necessary that you install a double pole switch
between the oven and the electricity supply (mains),
with a minimum gap of 3mm between the switch
contacts and of a type suitable for the required load in
compliance with the current rules.

The switch must not break the yellow and green earth
cable at any point.

Important

After installation and connecting, the cable must be
placed so that it cannot at any point reach a tempera-
ture of more than 60

°

C above the ambient temperature.

Before the oven is connected, check that the main
fuse and the domestic installation can support the
load; and that the power supply is properly earthed.

The manufacturer disclaims any responsibility
should these safety measures not be carried out.

DIMENSIONS

Height

580 mm.

OF RECESS

Width

560-570 mm.

Depth

550 mm.

DIMENSIONS

Height

320 mm.

OF THE

Width

420 mm.

OVEN CAVITY

Depth

390 mm.

Oven capacity

53.2 litres

Technical Data

The oven must be installed according to the
instructions supplied.

Heating elements rating

Oven element

2.08 kW

Grill element

1.82 kW

Oven Light

15 W

Cooling Fan

25 W

Convection Fan

30 W

Total Rating

2.15 kW

Connection

Min. size

Cable / flex Fuse

via

Cable/flex

type

• 13 A socket 2.5 mm

2

3 core

13 A

outlet

butyl

min.

• 13 A

insulated

spur box

• Cooker

2.5 mm

2

PVC/PVC

15 A min.

Control

twin and

20 A max.

Circuit

earth

For Uk use only

For Europe use only

Min. size Cable/flex

Cable / flex type

Fuse

1.5 mm

2

H05 RR-F

13 A