Electrical connections – Zanussi ZCE 531 GB User Manual

Page 7

Advertising
background image

7

ELECTRICAL CONNECTIONS

Any electrical work required to install

this hob and the supply cable should be
carried out by a qualified electrician or
competent person, in accordance with the
current regulations.

THIS COOKER MUST BE EARTHED.

The manufacturer declines any liability

should these safety measures not be
observed.

Before any maintenance or cleaning can

be carried out, you must DISCONNECT the
cooker from the electricity supply.

This cooker is designed to be connected to a
230-240V AC, 50Hz electrical supply.
To connect to the electricity supply, use cable
type H05 RR-F.

Before connection, make sure the electricity
supply voltage is the same as that indicated on
the rating plate.

The cooker is supplied without supply cable. A
flexible supply cable must be fitted, in
accordance with the specification gived in the
relevant table no. 1.

The electrical connection should be made using
a double pole isolating switch (cooker control
switch) with at least 3mm contact separation in
all poles. The cable must have conductors of
sufficiently high cross-sectional area to prevent
overheating or deterioration.

The switch should be sited within 2m of the
cooker and be easily accessible at all times.

The yellow-green grounding cable must not be
interrupted by the switch.

NOTE: The earth wire should be about 2 cm
longer than the live and neutral wires.

After installation and connecting, the cable must
be placed so that it cannot at any point reach a
temperature of more than 50°C above the ambient
temperature.

The manufacturer declines any responsibility
should these safety instructions not be carried
out.

If the supply cable is damaged, it must

be replaced by the manufacturer or its
service agent or a similarly qualified person
in order to avoid a hazard.

Before connecting check that:

• The fuse and household electrical

installation can carry the absorbed current of
the appliance (see rating plate);

• The cooker connection outlet or the cooker

control switch is easily accessible when the
appliance is installed.


How to proceed?

• Unscrew and remove the protective cover at

the back of the appliance;

• Connect the power cable to the terminal

block of the cooker according to the table
no.1;

• Secure by means of cable clamp;
• Make sure that the connection to the

terminal block is matching the supply
system, see table no.1;

• Refit and screw the protective cover on the

back of the appliance.

Table no. 1

Rated voltage

230 V 1N

Connection type

Single phase (UK)

Cable connection

to the terminal block

1 2 3 4 5

L1

N

PE

Mains Voltage

230 V

Voltage of heating elements

230 V

Fuse capacity

32 A

Cable section

3 x 6 mm

2