Figure 97 rfc 2684 routed pvc, Table 59 rfc 2684 routed pvc – ZyXEL Communications IES-612-51A User Manual

Page 197

Advertising
background image

Chapter 27 RFC 2684 Routed Mode

IES-612-51A User’s Guide

197

Figure 97 RFC 2684 Routed PVC

The following table describes the labels in this screen.

Table 59 RFC 2684 Routed PVC

LABEL

DESCRIPTION

Routed Domain

Click Routed Domain to open this screen where you can configure domains for
2684 routed mode traffic (see

Section 27.3 on page 198

).

RPVC ARP Proxy

Click RPVC ARP Proxy to go to the screen where you can view the Address
Resolution Protocol table of IP addresses of CPE devices using 2684 routed
mode and configure how long the device is to store them (see

Section 27.4 on

page 199

).

Routed Gateway

Click Routed Gateway to go to the screen where you can configure gateway
settings (see

Section 27.5 on page 200

).

Port

Use this drop-down list box to select a port for which you wish to configure
settings.

Gateway IP

Enter the IP address of the gateway to which you want to send the traffic that
the system receives from this PVC. Enter the IP address in dotted decimal
notation.

VPI

Type the Virtual Path Identifier for this routed PVC.

VCI

Type the Virtual Circuit Identifier for this routed PVC.

IP

Enter the subscriber’s CPE WAN IP address in dotted decimal notation.

NetMask

The bit number of the subnet mask of the subscriber’s WAN IP address. To find
the bit number, convert the subnet mask to binary and add all of the 1’s together.
Take “255.255.255.0” for example. 255 converts to eight 1’s in binary. There are
three 255’s, so add three eights together and you get the bit number (24).
Make sure that the routed PVC’s subnet does not include the IES-612-51A’s IP
address.

DS VC Profile

Use the drop-down list box to select a VC profile to use for this channel’s
downstream traffic shaping.

US VC Profile

Use the drop-down list box to select a VC profile to use for this channel’s
upstream traffic. The IES-612-51A does not perform upstream traffic policing if
you do not specify an upstream VC profile.

Add Click

Add to save your changes to the IES-612-51A’s volatile memory.

The IES-612-51A loses these changes if it is turned off or loses power, so use
the Config Save link on the navigation panel to save your changes to the non-
volatile memory when you are done configuring.

Cancel Click

Cancel to start configuring the screen again.

Index

This field displays the number of the routed PVC.

Port

This field displays the number of the DSL port on which the routed PVC is
configured.

Advertising