Electrical connection – Zanussi ZDM 868 User Manual

Page 29

Advertising
background image

29

Electrical Connection

The oven is designed to be connected to 230-240V
(50Hz) electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

or E

-

Earth terminal

THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given
below.

It is necessary that you install a double pole switch
between the oven and the electricity supply (mains),
with a minimum gap of 3mm between the switch
contacts and of a type suitable for the required load in
compliance with the current rules.

The switch must not break the yellow and green earth
cable at any point.

Important

After installation and connecting, the cable must be
placed so that it cannot at any point reach a
temperature of more than 60

°

C above the ambient

temperature.

Before the oven is connected, check that the main
fuse and the domestic installation can support the
load; and that the power supply is properly earthed.

The manufacturer disclaims any responsibility should
these safety measures not be carried out.

Connection

Min. size

Cable / flex Fuse

via

Cable/flex

type

• Cooker

6 mm

2

PVC/PVC

30 A

Control

twin and

Circuit

earth

For Uk use only

For Europe use only

Min. size Cable/flex

Cable / flex type

Fuse

4 mm

2

H05 RR-F

30 A

Advertising