Fault Finding

Preliminary Electrical Systems

Check

A. EARTH CONTINUITY CHECK - Appliance must

be electrically disconnected - meter set on (Ohms)

x 1 scale and adjust zero if necessary.
a) Test leads from any appliance earth point to earth

pin on plug. Resistance should be less than

0.1 (Ohm), check all earth wires for continuity

and all contacts are clean and tight.

B. INSULATION CHECK - Appliance electrically

disconnected, all switches ON.
a) meter set on (Ohms) x 1 scale.

Test leads from L to N in appliance terminal

block. If meter reads «0» then there is a short

circuit.

b) meter set on (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads

less than × (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed

but no fault is indicated - a detailed continuity check

(i.e. by disconnecting and checking each

component) is required to trace the faulty

component.
It is possible that a fault could occur as a result of

local burning/arcing but no fault could be found under

test. However a detailed visual inspection should

reveal evidence of burning around the fault.

START

Isolate appliance

and carry out:

A: Earth Continuity

check.

Has inlet fuse blown?

Carry out:

C: Polarity check.

Electricity supply

should now be

satisfactory.

Carry out:

D: Resistance to

Earth check.

Inlet wiring

faulty.

Rectify any

fault.

Isolate appliance and

carry out:

B: Insulation check.

Rectify any fault

including replacing

fuses as necessary.

SOCKET

(face view)

PLUG (with cover

removed)

Earth Wire

Green/Yellow

Neutral Wire

Blue

Brown Blue

Green

Yellow

Green

Yellow

Brown

Blue

( )

FUSE

( )

E

N

L

NO

YES

NO

YES

A. IGNITOR SWITCH

B. IGNITOR UNIT

B

L

N

0

1

2

3

4

5

6

220/240

A

Wiring Diagram