York YZB018 THRU 060 User Manual

Page 21

Advertising
background image

271457-YTG-B-0908

Johnson Controls Unitary Products

21

CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.

HEATING CAPACITY - YZB04811With Variable Speed Furnaces

VARIABLE

SPEED

FURNACE

COIL

1

MODEL

ARI HEATING

2

47

°F

17

°F

HSPF

MBH

COP

KW

MBH

COP

KW

STD

1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES

P(C,V)9*D20

FC/MC/PC60D

48.0

3.54

3.97

32.8

2.32

4.14

8.50

PV8*C20

FC/PC60C

48.0

3.50

4.02

33.2

2.30

4.23

8.00

P(C,V)9*C20

FC/PC60C

48.0

3.52

4.00

33.0

2.32

4.17

8.50

PV8*C20

HC60

48.0

3.50

4.02

33.2

2.30

4.23

8.00

P(C,V)9*D20

HC60

48.0

3.50

4.02

33.2

2.30

4.23

8.00

PV8*C20

HD60

48.0

3.50

4.02

33.2

2.30

4.23

8.00

P(C,V)9*D20

HD60

48.0

3.50

4.02

33.2

2.30

4.23

8.00

P(C,V)9*D20

MC61D

48.0

3.54

3.97

32.8

2.32

4.14

8.50

Y*9C*D20

FC/MC/PC60D 47.5 3.48 4.00 33.0 2.28 4.24 8.00

Y*9C*D20

FC/MC62D

48.0 3.54 3.97 32.8 2.30 4.18 8.10

Y*(8,L)C*C16

FC/PC60C

47.5 3.50 3.98 33.0 2.30 4.21 8.00

Y*(8,L)C*C20

FC/PC60C

47.5 3.54 3.93 32.8 2.32 4.14 8.10

Y*9C*C16

FC/PC60C

47.5 3.48 4.00 33.2 2.28 4.27 8.00

Y*9C*C20

FC/PC60C

47.5 3.48 4.00 33.2 2.28 4.27 8.00

Y*(8,L)C*C16

HD60

47.0 3.30 4.17 32.6 2.14 4.46 7.90

Y*(8,L)C*C20

HD60

47.0 3.32 4.15 32.4 2.16 4.40 7.90

Y*9C*C16

HD60

47.0 3.26 4.23 32.6 2.12 4.51 7.90

Y*9C*C20

HD60

47.0 3.26 4.23 32.6 2.12 4.51 7.90

Y*9C*D20

HD60

47.0 3.28 4.20 32.6 2.14 4.46 7.90

Y*(8,L)C*C16

UC60C

47.5 3.56 3.91 32.6 2.32 4.12 8.10

Y*(8,L)C*C20

UC60C

47.5 3.62 3.85 32.4 2.36 4.02 8.10

Y*9C*C16

UC60C

48.0 3.54 3.97 32.8 2.30 4.18 8.10

Y*9C*C20

UC60C

48.0 3.54 3.97 32.8 2.30 4.18 8.10

Y*9C*D20

UC60D

48.0 3.54 3.97 32.8 2.32 4.14 8.10

G*9V*D20

FC/MC/PC60D 47.5 3.48 4.00 33.0 2.28 4.24 8.00

G*9V*D20

FC/MC62D

48.0 3.54 3.97 32.8 2.30 4.18 8.10

G*9V*C16

FC/PC60C

47.5 3.48 4.00 33.2 2.28 4.27 8.00

G*9V*C20

FC/PC60C

47.5 3.48 4.00 33.2 2.28 4.27 8.00

G*9V*C16

HD60

47.0 3.26 4.23 32.6 2.12 4.51 7.90

G*9V*C20

HD60

47.0 3.26 4.23 32.6 2.12 4.51 7.90

G*9V*D20

HD60

47.0 3.28 4.20 32.6 2.14 4.46 7.90

G*9V*C16

UC60C

48.0 3.54 3.97 32.8 2.30 4.18 8.10

G*9V*C20

UC60C

48.0

3.54 3.97 32.8 2.30 4.18 8.10

G*9V*D20

UC60D

48.0 3.54 3.97 32.8 2.32 4.14 8.10

Notes listed below.

HEATING CAPACITY - YZB06012With Variable Speed Furnaces

VARIABLE

SPEED

FURNACE

COIL

1

MODEL

ARI HEATING

2

47

°F

17

°F

HSPF

MBH

COP

KW

MBH

COP

KW

STD

1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES

P(C,V)9*D20

FC/MC62D

55 3.54 4.55 37 2.46 4.35 8.65

Y*(8,L)C*C20

FC/MC62D

56.5 3.56 4.65 34.0 2.40 4.15 8.10

Y*9C*C20

FC/MC62D

57.0 3.50 4.77 34.2 2.36 4.25 8.00

Y*9C*D20

FC/MC62D

57.0 3.50 4.77 34.0 2.38 4.19 8.10

G*9V*C20

FC/MC62D

57.0 3.50 4.77 34.2 2.36 4.25 8.00

G*9V*D20

FC/MC62D

57.0 3.50 4.77 34.0 2.38 4.19 8.10

1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no

supplemental electric heat operation.

Advertising