Pump Installation and Wiring Diagram

1. Submersible

ef

fl u ent turbine pumps may be installed in any ap pli ca tion

where relatively clear effl uent, such as from a dos ing tank or high
head STEP system etc., is being pumped.

2. Pumps should always be installed vertically. Pumps should never

be installed horizontally.

3. Because of their low temperature rise, pumps under 2 HP do not

require a fl ow inducer sleeve.

4. Mount the junction box in its permanent position.

5. Run prewired conduit, or equivalent submersible cable from the

junc tion box to a fused disconnect or, if applicable, the control
panel.

6. Feed the pump power cord and fl oat switch cords into the junc tion

box.

7. Make the connections in the junction box using the wiring di a grams

below. If you are using a con trol panel or a fi ltered STEP system,
follow the wiring di a grams and in struc tions included with them.

8. An alarm should be used with any system using a pump. Follow

the wiring diagram with the alarm for installation and check your
local codes.

9. Run the appropriate power to the control panel from a fused (cir cuit

breaker) disconnect. The appropriate power supply in for ma tion
may be found on the pump nameplate.

10. To provide a suitable ground, a separate ground wire (green or

bare) at least as large as the line conductors is required. It is
connected from the electrical disconnect box to the con trol panel,
to the junction box and to the green ground wire of the submersible
motor lead.

11. Always disconnect all power when installing or ser vic ing the

pump.

SK2221A

SK2221B

SK2250

TO

POWER SUPPLY

TO

FLOAT SWITCHES

GREEN

BLACK

GREEN

WHITE

RED

BLK

YEL

L2

L1

CONTROL PANEL

ZOELLER 230 VOLT

EFFLUENT TURBINE PUMP

2HP & 3HP

FRANKLIN ELECTRIC
CAPACITOR BOX

GR

EEN

115V

FLOAT SWITCH

115 VOLT LINE

GROUND

BL

AC

K

W

HITE

BL

AC

K

W

HITE

115 VOLT

FUSED DISCONNECT

(CIRCUIT BREAKER)

JUNCTION
BOX

ZOELLER 115 VOLT

EFFLUENT TURBINE PUMP

1/2HP

W

HITE

BL

AC

K

W

HITE

GR

EEN

W

HITE

BL

AC

K

BL

AC

K

BLACK

WHITE

WHITE

WHITE

BLACK

BLACK

BLACK

WHITE

WHITE

BLACK

230 VOLT LINE

GROUND

JUNCTION

BOX

230V

FLOAT SWITCH

GREEN

GREEN

ZOELLER 230 VOLT

EFFLUENT TURBINE PUMP

1/2HP - 1 1/2HP

230 VOLT

FUSED DISCONNECT

(CIRCUIT BREAKER)