User instructions, Extended burning, Over-firing – Yeoman DEVON 50 User Manual

Page 11: Chimney fire

Advertising
background image

9. eXtended BuRnInG

9.1 It is possible to get the appliance to burn for extended

periods. In order to do this:

De-ash prior to final refuelling.

Set air controls to low combustion settings. This will

blacken the glass over night but it will clear when

operated at high output for a short period.

Use smokeless fuel or small, thick logs depending on fuel

desired.

10. oveR-FIRInG

10.1 Do not over-fill with fuel or use at maximum output for

long periods or over-firing can occur. If the flue pipe, flue

collar or top plate glow red the appliance is over-firing.

Close the air controls to reduce the output.

10.2 Over-firing can cause permanent damage to the appliance.

11. cHIMney FIRe

11.1 If a chimney fire occurs:

Shut all air controls immediately.

Evacuate the building.

Call the fire brigade.

Do not re-enter the building until it is confirmed safe.

11.2 do not use the appliance after a chimney fire until:

a) It has been inspected by a registered installer,

confirming the appliance is safe to use*.

b) The chimney system inspected and swept by a chimney

sweep, confirming the system is structurally sound and

free from obstruction before re-use**.

c) It is repaired as required before re-use. Use only

genuine Stovax replacement parts to keep your appliance

in safe and efficient working order.

useR InstRuctIons

11

PR8883

Place flat on the fixings on the bottom of the appliance

(see Diagram 12).

12

PR8884

Fit the plug supplied in the right hand side where the

riddling mechanism is located (see Diagram 13).

13

PR8454

Plug

Clamp

Bolt

Replace the log bar.

11

* Registered on the Competent Persons Scheme (UK only)

see page 14 / INFO (Republic of Ireland).

**This should be done by a HETAS Approved Chimney

Sweep (UK only) see page 14 / INFO registered (Republic

of Ireland only) who will issue you with a certificate.

Advertising