Driver Installation

This section covers driver installation for the NetBlaster adapter. At this stage the adapter should
be secure in the system and all Ethernet cables should be attached. If this is not the case, return

to the “Hardware Installation” procedure in the previous section.

Download the specific driver for your system from the ZNYX web site (

www.znyx.com

).

Included on the web site with the driver are release notes with installation and configuration

instructions. Follow the directions on line to configure the driver.

Running DOS Diagnostics

DOS-based diagnostics are also available from the ZNYX web site (

www.znyx.com

) to help

troubleshoot hardware problems. If you believe you have a hardware problem, and have the

capability to run DOS-based diagnostics, the steps below outline the use of the diagnostics.

Testing ZX478 Adapters in DOS

1. Run the diagnostic program to see if your adapter has been properly configured. Run

DIAG478.EXE off your diskette by entering:

>DIAG478 LIST

2. You will see a list below. (This example is for the ZX478.)

DIAG478 Version 2.04 for ZNYX NetBlaster ZX478

8/100 Mbps adapter

(c) Copyright 1994-1999 ZNYX Corporation - All Rights Reserved.
PCI BIOS Information: Version=2.10, Config Mechanism=1, Last Bus=2

Bus Dev Fn

Vendor Device Rev

Type

Lat IL IRQ

Note

==========

=================

============

==========

=====

0

0

0

8086

1250

03

Host Bridge

20

-

-

0

7

0

8086

7000

01

PCI-ISA

00

-

-

0

7

1

8086

7010

00

IDE

20

-

-

2

12

0

1011

0046

01

Ethernet

73

A

10

ZX478

2

412

0

1011

0019

41

Ethernet

73

A

10

ZX478

2

512

0

1011

0019

41

Ethernet

73

A

10

ZX478

2

612

0

1011

0019

41

Ethernet

73

A

10

ZX478

2

712

0

1011

0019

41

Ethernet

73

A

10

ZX478

2

812

0

1011

0019

41

Ethernet

73

A

10

ZX478

2

912

0

1011

0019

41

Ethernet

73

A

10

ZX478

2 1012

0

1011

0019

41

Ethernet

73

A

10

ZX478

2 1112

0

1011

0019

41

Ethernet

73

A

10

ZX478

1

0

0

8086

7800

21

VGA

0

A

5

3. You should see nine Ethernet-type devices (one the bridge, and one for each of the eight

ports), and the “Note” column should indicate the device to be a ZX478. Each should have

an IRQ (interrupt line), bus value, and a unique device number. If so, your card has been

automatically configured. Make a note of the bus and device numbers and go on to the

software installation section.