background image

– 15 –

4. Pull slowly on the recoil starter until it is engaged,

then pull it briskly.

5. After the engine starts, warm up the engine until

the engine does not stop when the choke lever is
returned to the operating position.

6. Turn the choke lever back to the operating posi-

tion.

1 Operating position

704-010

701-025

q

NOTE:

9 “–” means below.
9 Application wattage indicates when each appara-

tus is used by itself.

c

C

Be sure the total load is within generator rated out-
put otherwise generator damage will occur.

NOTE:

Some precision equipment is voltage sensitive and
may require a more uniform voltage supply than
portable generators provide. Examples include some
medical equipment, personal computers, and some
inverters that sense peak and RMS voltage values.
Consult the precision-equipment vendor before relying
on any portable generator to provide power to such
equipment.

AE00343

APPLICATION RANGE

AC

Power factor

1

0.8–0.95

0.4–0.75

(Efficiency 0.85)

EF1600

–1,400W

–1,120W

–480W

EF2600

YG2600

–2,300W

–1,840W

–780W

779-006a

779-006c

779-006b