COOLING CAPACITY - COIL ONLY

*

Model Coil

Rated CFM

Entering Air °F

(Wet Bulb)

MBH@ Evaporator Temperature and Corresponding Pressure °F / PSIG

35 / 61.5

40 / 68.5

45 / 76.0

50 / 84.0

FULL-CASED “A” TYPE MULTI-POSITION

MC18A

550

72

25.8

23.5

21.0

18.2

67

23.7

21.5

19.0

16.4

62

19.5

17.3

14.9

12.6

57

15.8

13.5

11.5

9.0

MC18B

650

72

28.7

26.1

23.3

20.2

67

26.4

23.9

21.1

18.2

62

21.6

19.2

16.6

14.0

57

17.5

15.2

12.8

10.0

MC24A
MC24B

850

72

36.3

33.0

29.5

25.6

67

33.4

30.2

26.7

23.1

62

27.4

24.3

21.0

17.7

57

22.2

19.3

16.2

12.6

MC30A
MC30B

1025

72

41.5

37.8

33.7

29.5

67

36.2

32.4

28.6

24.5

62

29.1

25.3

24.0

19.2

57

24.1

21.5

18.7

15.8

MC35B
MC35C

1025

72

46.9

42.7

38.2

33.6

67

37.6

33.2

29.1

24.7

62

29.3

24.6

26.9

20.0

57

25.2

23.3

21.5

20.0

MC36A

1150

72

46.8

42.6

38.1

33.6

67

37.5

33.1

29.1

24.7

62

29.3

24.6

26.8

20.0

57

25.1

23.2

21.4

20.0

MC36B

1250

72

52.0

47.3

42.3

37.3

67

41.7

36.8

32.3

27.4

62

32.5

27.3

29.8

22.2

57

27.9

25.8

23.8

22.2

MC36C

1250

72

53.4

48.6

43.4

38.3

67

42.8

37.8

33.1

28.2

62

33.4

28.1

30.6

22.8

57

28.7

26.5

24.5

22.8

MC42B
MC42C

1400

72

88.4

76.0

63.3

50.0

67

70.8

59.4

48.4

37.0

62

55.2

43.9

35.8

29.9

57

47.4

41.5

35.8

29.9

MC48C
MC48D

1650

72

100.5

86.4

72.0

56.8

67

80.4

67.5

55.0

42.1

62

62.7

49.9

40.7

34.0

57

53.9

47.2

40.7

34.0

MC60D

1825

72

119.9

101.0

80.0

62.2

67

96.0

79.2

62.6

45.8

62

74.8

58.6

46.2

37.0

57

64.3

55.4

46.2

37.0

MC61D

2000

72

124.8

105.2

85.3

64.7

67

99.9

82.5

65.2

47.7

62

77.9

61.1

48.1

38.6

57

66.9

57.7

48.1

38.6

* See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity.