Installa tion - in ternal blo w e r – Zephyr ARC AHZ-M90ABX User Manual

Page 11

Advertising
background image

Installa

tion - In

ternal Blo

w

e

r

4. Rotate the blower plate

(Note! If air is discharged
from the top, do not rotate
the plate).Place the 6" metal-
lic fl ange on the blower's air
outlet (the fl ange may alre-
ady be pre-installed). Install
internal blower into blower
plate and secure using (4)
screws included with the blo-
wer. See Fig.4

5. Fasten the two brackets to the

sides of the blower by fi xing
them onto the blower plate
with the (4 type B) screws,
and to the sides of the blower
with other (4 type C) screws.
Fig 5


6. Secure capacitor box con-

nected to the provided
cable to the blower plate
using (2 type B) screws in-
cluded with the blower. See.
Fig.6

7. Secure Green/Yellow ground

wire connected to the cable
to the provided capacitor to
blower plate. (type A). Fig.7

- 11 -