Installation, Gas connection, Cut out size – Zanussi GAS HOB ZGF 982 User Manual

Page 11

Advertising
background image

12

Rectangular cut-out size for hob

A) End of shaft with nut
B) Washer
C) Elbow

It is important to install the elbow correctly,
with the shoulder on the end of the thread,
fitted to the hob connecting pipe.
Failure to ensure the correct assembly will
cause leakage of gas.

FO 0814

Gas Connection

Connection to the gas supply should be with either
rigid or semi-rigid pipe, i.e. steel or copper.
The connection should be suitable for connecting to
RC 1/2 (1/2 BSP male thread).
When the final connection has been made, it is
essential that a thorough leak test is carried out on the
hob and installation.
Ensure that the main connection pipe does not exert
any strain on the hob.

Dimensions are given in mm.

Installation

IMPORTANT

This hob must be installed by qualified
personnel
to the relevant British Standards.

Any gas installation must be carried out by
a registered CORGI installer.

The manufacturer will not accept liability,
should the above instructions or any of the
other safety instructions incorporated in this
book be ignored.

On the end of the shaft, which includes the GJ 1/2"
threaded elbow, adjustment is fixed so that the washer
is fitted between the components as shown in the
diagram. Screw the parts together without using
excessive force.

FO 0264

Cut Out Size

The dimensions of the cut-out are given in the
diagram.

830

480

55 min.

30

150 min

FO 2349

Advertising