Appendix, Specifications, General specifications – Yamaha 12/4 User Manual

Page 27

Advertising
background image

MG16/4, MG12/4

27

Appendix

General Specifications

Where 0 dBu = 0.775 V and 0 dBV = 1 V

1

Measured with 12.7 kHz, –6 dB/oct. low pass filter (equivalent to 20 kHz, –

∞ filter).

(CH MIC INPUT to ST, GROUP OUT/AUX, EFFECT SEND)

2

Turning PAN/BAL to left or right.

3

Shelving turnover/rolloff frequency: 3 dB before maximum cut or boost.

Specifications

Frequency Characteristics

20 Hz–20 kHz +1 dB, –3 dB @+4 dBu, 600

(with gain control at maximum level)

Total Harmonic Distortion

0.1 % (THD+N) @+14 dBu, 20 Hz–20 kHz, 600

(with gain control at maximum level)

Hum and Noise

1

–128 dBu

Equivalent input noise 150

(MG16/4: CHs 1 to 8,

MG12/4: CHs 1 to 4)

–100 dBu

Residual output noise (ST OUT)

–88 dBu (92 dB S/N)

ST, GROUP Master fader at nominal level and all Ch
assign SW’s off.

–81 dBu (85 dB S/N)

AUX master control at nominal level; all channel mix
controls at minimum level.

–64 dBu (68 dB S/N)

ST, GROUP Master fader and one Ch fader at nominal
level. (MG16/4 CH1–8, MG12/4 CH1–4)

Maximum Voltage Gain

2

60 dB CH MIC INPUT

CH INSERT OUT

84 dB CH MIC INPUT

GROUP OUT/ST OUT (CH to ST)

94 dB CH MIC INPUT

ST OUT (GROUP to ST)

62.2 dB CH MIC INPUT

REC OUT (CH to ST)

76 dB CH MIC INPUT

AUX SEND (PRE)

86 dB CH MIC INPUT

AUX SEND (POST)

58 dB CH LINE INPUT

GROUP OUT/ST OUT (CH to ST)

84 dB ST CH MIC INPUT

GROUP OUT/ST OUT (CH to ST)

58 dB ST CH LINE INPUT

GROUP OUT/ST OUT (ST to ST)

47 dB ST CH LINE INPUT

AUX SEND (PRE)

57 dB ST CH LINE INPUT

AUX SEND (POST)

34 dB ST CH INPUT

GROUP OUT/ST OUT (ST to ST)

16 dB AUX RETURN

ST OUT

9 dB AUX RETURN

AUX SEND

27.8 dB 2TR INPUT

ST OUT

Monaural/Stereo Input Gain Control

44 dB variable

Monaural/Stereo High Pass Filter

80 Hz 12 dB/octave

Crosstalk (1 kHz)

–70 dB between input channels
–70 dB between input/output channels (CH INPUT)

Monaural/Stereo Input Channel Equalization:

Max. Variation

3

±15 dB
HIGH 10 kHz shelving
MID 2.5 kHz peaking
LOW 100 Hz shelving

Monaural/Stereo Input Peak Indicator

On each channel: red indicator lights if post-EQ signal (on ST channels, if either post-EQ sig-
nal or post-mic-amp signal) comes within 3 dB of the clipping level.

Level Meters

Two 12-point LED meters
Peak point: red indicator
+5, +3, +1, and 0 points: yellow indicators
–1, –3, –5, –7, –10, –15, –20: green indicators

Phantom +48 VDC Power (Balanced input)

Supplied when Phantom +48 V switch is ON.

Included Accessory

Power adaptor (PA-20)

Power Supply

USA and Canada:

120 V

AC, 60 Hz

Europe:

230 V

AC, 50 Hz

Australia:

240 V

AC, 50 Hz

Korea:

220 V

AC, 60 Hz

Power Consumption

MG16/4: 36 W

MG12/4: 29 W

Max. Dimensions (W

×

H

×

D)

MG16/4: 423

Ч

108

Ч

416.6 mm

MG12/4: 322

Ч

108

Ч

416.6 mm

Weight

MG16/4: 5.2 kg

MG12/4: 5.0 kg

Advertising