Operating procedures, Spare parts – Zenith 216666666 User Manual

Page 6

Advertising
background image

Page 6

Z

enithenithdor - Installation & Operating Instructions - 81333 - May 20

Operating Procedures

Water Temperature

Z

enith Tudor water heaters are fully automatic, and may be left switched ON

under the control of the variable thermostat.

Nominal operating temperature can be varied from about 30°C to about 80°C.

Temperature should not be set to less than 60°C without due regard to
regulations governing the storage temperature of hot water.

Economy Setting

The economy setting "E" will maintain stored water temperature at
approximately 60°C. At the "E" setting, the temperature control locates into a
set position and a slight resistance will be felt when rotating the temperature
control beyond that setting. This measure is to help ensure that higher
temperatures are only selected deliberately.

Frost Protection

If the heater is located where ambient air temperature could fall below 5°C
when the heater is not in use, the "anti freeze" setting on the temperature
control will maintain stored water temperature over 5°C to prevent freezing
and damage to the water heater.

The same protection does not extend to connecting pipework or fittings.

Safety Cutout

Should the heater over-heat, a manually resettable safety cutout will
automatically turn the heating element OFF. The cutout must be reset by a Z

enith

Service Provider or a licensed electrician. Users should never reset the cutout
without qualified assistance.

Cleaning

Never use strong, corrosive or abrasive cleaning materials. Wipe clean the
outer surfaces with a sponge or soft cloth using a mild soap and water.
Domestic dish washing liquid detergent is most suitable.

ECONOMY

HIGH

OFF

ANTI-

FREEZE

LOW

PART NO DESCRIPTION

Z90401

element neck ring kit Tudor

Z90407

fascia kit Tudor undersink

Z90408

fascia kit Tudor oversink

Z90415

element kit Tudor 5ltr o/sink

Z90416

element kit Tudor 10ltr o/sink

Z90417

element kit Tudor 5ltr u/sink

Z90418

element kit Tudor 10ltr u/sink

Z90420

pilot light kit Tudor

Z90421

thermostat kit Tudor

Z90423

overload kit Tudor