Yamaha STAGEMIX M7CL User Manual

Page 16

Advertising
background image

Yamaha Commercial Audio M7CL StageMix User Guide V1.5

Page 16

4.6.1 HPF

When the HPF is selected, an extra [HPF] button appears at the top of
the EQ graph. Press this button to switch the HPF on/off. When the
button is green, the HPF is On. HPF has no Gain or Q parameter: only
frequency.


4.6.2 EQ Bands 1 & 4

EQ bands 1 & 4 have additional choices of band-type. Both these
bands can be a shelf or a bell, and band 4 can also be a Low Pass
Filter. Band 1 can also be a HPF for Mix/Matrix channels. When one
of these bands is selected, the relevant additional buttons are shown
above the EQ graph.


4.6.3 EQ

ON

The channel EQ can be switched on/off with the [EQ ON] button
towards the top-right of the EQ graph. It is green when the EQ is on.
When the EQ is switched off, the EQ curve will be grey.

4.6.4 EQ FLAT, EQ DEFAULT

These two buttons, above the EQ curve perform the same function as
those on the M7CL console. [FLAT] will set the Gain of bands 1-4 to
0dB, but will not change the Q and Frequency values. [DEFAULT] will
reset all EQ parameters for the selected channel back to their default
values, including HPF.
After pressing one of these buttons, an “Are You Sure?” pop-up will be
displayed before the action is carried out (or cancelled).

To exit from the EQ window and return to the Mixer window, press the
[MIXER] button at the top-right of the display.

Advertising