This oven must be installed by qualified

personnel to the relevant British Standards.

Electrical Connection

Installation

The oven is designed to be connected to 230-240V (50Hz)

electricity supply.

The oven has an easily accessible terminal block which

is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

or E

-

Earth terminal

THIS OVEN MUST BE EARTHED

The cable used to connect the oven to the electrical

supply must comply to the specifications given below.

It is necessary that you install a double pole switch

between the oven and the electricity supply (mains), with

a minimum gap of 3mm between the switch contacts and

of a type suitable for the required load in compliance with

the current rules.

The switch must not break the yellow and green earth

cable at any point.
Important
After installation and connecting, the cable must be

placed so that it cannot at any point reach a temperature

of more than 60°C above the ambient temperature.

Before the oven is connected, check that the main fuse

and the domestic installation can support the load; and

that the power supply is properly earthed.

The manufacturer disclaims any responsibility should

these safety measures not be carried out.

Technical Data

Dimensions of recess

Height

580 mm.

Width

560-570 mm.

Depth

550 mm.

Dimensions of the oven cavity

Height

325 mm.

Width

420 mm.

Depth

390 mm.

Oven capacity

53 litres

The oven must be installed according to the

instructions supplied.

Heating elements rating

Oven element

2,088 W

Grill element

1,830 W

Oven Light

15 W

Cooling Fan

25 W

Convection Fan

30 W

Total Rating

2,150 W

Supply voltage (50 Hz)

230-240 V

Connection

Min. size

Cable / flex Fuse

via

Cable/flex type

• 13 A socket 2.5 mm

2

3 core

13 A

outlet

butyl

min.

• 13 A

insulated

spur box

• Cooker

2.5 mm

2

PVC/PVC

15 A min.

Control

twin and

20 A max.

Circuit

earth

For Europe use only

Min. size Cable/flex Cable / flex type

Fuse

1.5 mm

2

H05 RR-F, H05 VV-F 13 A

H05 V2V2-F (T90)

H05 BB-F

For Uk use only