Charger configuration, Force charger to float charge, Force charger to equalize charge – Xantrex Technology PROSINE PS3.0 User Manual

Page 51

Advertising
background image

ACS Configuration Considerations

34

Prosine 2.5/3.0 Installation & Operation Guide

The voltage range for these alarms and cutoffs is generally set at the factory at the absolute minimum
and maximum, as shown in the illustration above for 12-volt systems. Example: Lo Cutoff = 10.0V, Hi
Cutoff = 16.0V, Range = 10.0 to 16.0 volts DC. The table below illustrates the factory settings and the
min–max range for both 12-volt and 24-volt systems.

Charger Configuration

The ACS Charger menu displays the current status of the charger and enables you to begin an
equalization charge, or to override the current charger status and force the charger into Float or
Equalization mode.

Override Charger Operating Mode The charger will not begin an equalization charge until it has
completed a Bulk or Absorption charge. It may be desirable to force an equalization charge in some
instances. Forcing the charger into Float or Equalization mode is usually performed only during an
installation, and should not be lightly considered. Consult your installer or call Xantrex Customer
Service before attempting to override the charger mode. Overriding the charger operating mode is an
installer-configuration item. The menu procedure is illustrated below.

Enter “Installer Mode, and then:

Equalization Request For some batteries, equalization is a regular maintenance activity; for
others, equalization is damaging. Read

“Section 6: Multistage Charging”

(

page 59

) before attempting

to initiate an equalization charge. Inappropriate equalization charging can ruin your batteries. An
equalization request is a user-configuration item: press ENTER at the menu and follow the prompts
shown below to initiate an equalization request. When you press ENTER at the YES prompt,
equalization will begin immediately if the batteries are fully charged, and AC power is available.
Since equalization voltage is usually above the range of the High Voltage Alarm, an audible alarm will
sound briefly when it is enabled. The Faults and Charger LEDs will also flash as a visual alarm. This

High and Low Voltage Alarms and Cutoffs

ALARM OR CUTOFF

12-VOLT MIN-

MAX RANGE

Factory

Default

24-VOLT MIN-

MAX RANGE

Factory

Default

LO ALARM

10.0V - 12.0V

10.5V

20.0V - 24.0V

21.0V

HI ALARM

14.0V - 16.0V

15.5V

28.0V - 32.0V

31.0V

LO CUTOFF

10.0V - 12.0V

10.0V

20.0V -24.0V

10.0V

HI CUTOFF

14.0V - 16.0V

16.0V

28.0V - 32.0V

16.0V

OVERRIDE CHARGER
OPERATING MODE

SELECT FROM:
CHARGER

ENTER

FORCE CHARGER TO
FLOAT CHARGE

ENTER

FORCE CHARGER TO
EQUALIZE CHARGE

ENTER