Electrical connection – Zanussi ZSA 15 User Manual

Page 6

Advertising
background image

7

ELECTRICAL CONNECTION

We strongly recommend that all operations for the
installation of your oven be carried out by
QUALIFIED PERSONNEL to the relevant British
Standards.

The oven designed to be connected to 240V (50Hz)
electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

-

Earth terminal

THIS APPLIANCE MUST BE EARTHED

The cable used to connect the oven to the electrical
supply should have the characteristics indicated in
the table.

It is necessary that you install a double pole switch
between the appliance and theelectricity supply
(mains), with a minimum gap of 3mm between the
switch contacts and of a type suitable for the
required load in compliance with the current rules.

The switch must not break the yellow and green
earth cable at any point.

Important

After installation and connecting, the cable must be
placed so that it cannot at any point reach a
temperature of more than 50

°

C above the ambient

temperature.

Before the appliance is connected, check that the
main fuse and the domestic installation can support
the load; and that the power supply is properly
earthed.

The manufacturer disclaims any responsibility should
these safety measures not be carried out.

This appliance meets the requirements laid down in
EEC Directive No. 89/336 relating to the suppression
of radio and TV interference.

Models

Rating

Cable cross

Fuse

section mm

2

and

Type of the cable

min.

ZSA15

2565 W

6 mm

2

6242 Y

15 A

For Uk use only

Models

Rating

Cable cross

Fuse

section mm

2

and

Type of the cable

min.

ZSA15

2565 W

2,5 mm

2

Ho5 RR-F

13 A

For Europe use only