Installation – remote blower preparation – Zephyr Cypress AK7842ASX User Manual

Page 14

Advertising
background image

12

www.zephyronline.com

Installation –

Remote Blower Preparation

1. Place 10” round adapter on top of hood and

secure with (4) M4x8 screws. Connect 10”
round duct work to 10” round adapter.

2. Install threaded end of external blower wiring

through external blower wiring knock out
located inside the hood.

3. Place cap over threaded end of external blower

wiring and secure by turning clockwise.

4. Connect 6 pin male connector from external

blower wiring to 6 pin female connector on
control board wire inside hood. Secure green
ground wire from external blower wiring to
ground screw on hood.

NOTE: For instructions on mounting the external and in-line blowers, please refer to the manual included
in the blower packaging or on our website: www.zephyronline.com


REMOTE BLOWER: WIRING DIAGRAM

White (common)
Black (high)
Blue (med)
Red (low)
Green (ground)

Remote Blower

Wiring Box

(hood)

Junction Box

(Remote Blower)

CBE-1000 EXTERNAL OR PBN-1000A IN-LINE BLOWER INSTALLATION