Installation – remote blower preparation – Zephyr AK8200AS User Manual

Page 14

Advertising
background image

12

www.zephyronline.com

Installation –

Remote Blower Preparation

1. Place 8” round adapter on top of power pack

and secure with (4) M4x8 screws. Connect 8”
round duct work to 8” round adapter.

2. Install threaded end of remote blower wiring

through external blower wiring knock out (B)
located in junction box on top of power pack.

3. Place cap over threaded end of remote blower

wiring and secure by turning clockwise.

4. Connect 6 pin male connector from blower

wiring to 6 pin female connector in the power
pack. (plug is located inside the power pack
protruding from the white control board box).

NOTE: For instructions on installing remote blowers, please refer to the CBE-1000 or PBN-1000A

manuals included in the blower packaging and on our website: www.zephyronline.com


CBE-1000 / PBN-1000A: WIRING DIAGRAM

White (common)
Black (high)
Blue (med)
Red (low)
Green (ground)

Remote Blower

Wiring Box

(hood)

Junction Box

(Remote Blower)

B

B

A

A: Ground wire screw
location (inside)

5. Secure green ground wire from remote
blower wiring to ground screw located
inside the power pack