TROUBLESHOOTING PROCEDURES FOR TORNADO II AND TORNADO III

Issue

Cause

What to do

After installation,
the unit doesn’t
work.

1. The power source is not turned ON.

1. Make sure the circuit breaker and the unit’s

power is ON.

2. The power line and the cable locking connector

is not connecting properly.

2. Check the power connection with the unit is

connected properly.

3. The switch board and control board wirings are

disconnected.

3. Make sure the wirings between the switch

board and control board are connected
properly.

4. The wires on control board are loose.

4. Make sure the wires on the control board are

connected properly.

5. The switch board or control board is defective.

5. Change the switch board or control board.

Light works,
but motor is not
turning.

1. The motor is defective, possible seized.

1. Change the motor.

2. The thermally protected system detects if the

motor is too hot to operate and shuts the motor
down.

2. The motor will function properly after the

thermally protected system cool down.

3. Damaged capacitor.

3. Change the capacitor.

4. The motor wire is not connected.

4. Make sure the motor wire is plugged into the

molex connector.

The unit is
vibrating.

1. The motor is not secure in place.

1. Tighten the motor in place.

2. Damaged blower wheel.

2. Change the blower.

3. The hood is not secured in place.

3. Check the installation of the hood.

The motor is
working, but the
lights are not.

1. Defective halogen bulb.

1. Change the halogen bulb.

2. The light bulb is loose.

2. Tighten the light bulb.

3. The wires on the control board are loose.

3. Make sure the wires on control board are

connected properly.

The hood is
not venting out
properly.

1. The hood might be hanging too high from the

cook top.

1. Adjust the distance between the cook top and

the bottom of the hood within 26” and 36”
range.

2. The wind from the opened windows or opened

doors in the surrounding area are affecting the
ventilation of the hood.

2. Close all the windows and doors to eliminate

the outside wind fl ow.

3. Blockage in the duct opening or duct work.

3. Remove all the blocking from the duct work or

duct opening.

4. The direction of duct opening is against the wind.

4. Adjust the duct opening direction.

5. Using the wrong size of ducting.

5. Change the ducting to correct size.

Filter is vibrating.

1. Filter is loose.

1. Adjust or change the fi lter.

2. Spring clip is broken inside fi lter opening

2. Change the spring clip.

RF Remote
control does not
work

1. Battery is dead

1. Replace battery with type A23 12v

2. Poor communication with the power pack

2. Remote control must be within 15 ft of power

pack

3. RF remote lost communication with power pack

3. Reset power pack and remote by switching

power off at the circuit breaker for 5 minutes.
Pace remote on counter top near power pack
and switch the circuit breaker back on.

The blower turns
on by itself.

1. The clean air function has been enabled turning

the blower on every 4 hours.

1. Disable the clean air function by following the

steps on page 14.

Advertising