Installation – mounting height & clearance – Zephyr AK8200AS User Manual

Page 8

Advertising
background image

Installation –

Mounting Height & Clearance

6

www.zephyronline.com

DUCTING

A minimum of 6” round or 3-1/4” x 10” rectangular
duct must be used to maintain maximum air fl ow
effi ciency for single blower and 8” round duct for
dual and remote blowers.

Always use rigid type metal ducts only. Flexible
ducts could restrict air fl ow by up to 50%.

Also use calculation (on page 5) to compute total
available duct run when using elbows, transitions
and caps.

ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size.

If turns or transitions are required; install as far
away from hood duct output and as far apart,
between the two as possible.

Minimum mount height between range top to hood
bottom should be no less than 26”.

Maximum mount height should be no higher than
36”.

It is important to install the hood at the proper
mounting height. Hoods mounted too low could
result in heat damage and fi re hazard; while hoods
mounted too high will be hard to reach and will
lose its performance and effi ciency.

If available, also refer range manufacturer’s height
clearance requirements and recommended hood
mounting height above range.

AK8200AS
Vertical Ducting:
8” round minimum (dual blower)
Horizontal Ducting:
N/A

AK8300ASX
Vertical Ducting:
6” round minimum (single blower)
8” round minimum (dual and remote blowers)
Horizontal Ducting:
N/A

DAMAGE-SHIPMENT / INSTALLATION:
• Please fully inspect unit for damage before

installation.

• If the unit is damaged in shipment, return the

unit to the store in which it was bought for
repair or replacement.

• If the unit is damaged by the customer, repair

or replacement is the responsibility of the
customer.

• If the unit is damaged by the installer (if other

than the customer), repair of replacement must
be made by arrangement between customer
and installer.

Min 26" - Max 36"

36"

Advertising