11 Troubleshooting

PROBLEM: AC product will not operate, no audio alarm.

PROBLEM: AC product will not operate, audio alarm is

sounding

PROBLEM: Run time is less than expected.

Possible Cause

Product rated more than 230 watts,

safety overload circuit has tripped.
Appliance is rated less than 230 watts,

high starting surge has tripped

overload.

Suggested Remedy

Use an AC product with a power rating

less than 230 watts.
AC product may exceed Portable Power

250’s surge capability. Use an AC

product with starting surge power

within the unit’s surge rating.

Possible Cause

Battery has discharged to 10.0 volts.

Inverter has overheated due to poor

ventilation or excessively warm

environmental conditions.

Suggested Remedy

Turn off AC product and recharge

battery.
Turn inverter OFF and allow to cool

for 15 minutes. Clear blocked fan

opening or remove objects covering

the unit then restart.

Possible Cause

Internal battery is not fully charged.

AC product power consumption is

higher than expected.

Suggested Remedy

Recharge using AC Charger, until

Recharge Indicator is green.
Check AC product power or “wattage”

rating (or current draw for DC products)

and compare with tables in Sections

5.5 and 6.3.