4. CONNECTING TO GAS

This appliance is designed to be installed with an appliance flexible connection only. Supply piping should not
be less that R³/8. Connection is made to the Rc ½ (½" B.S.P.) female threaded entry pipe located just below

the hotplate level on the rear left hand side of the appliance.

NOTE: ONLY LIQUID SEALANTS TO BE

USED WHEN INLET GAS PIPE IS FITTED TO RESET VALVE I.E.: DO NOT USE P.T.F.E. SEALANT
TAPE.

Check for gas soundness after connecting the gas supply.

The gas bayonet connector must be fitted in the shaded
area indicated in Fig. 3. Take into account that it must be
possible to pull the appliance forward sufficiently. The
hose must not get caught on the stability bracket.
IMPORTANT: FLEXIBLE TUBING USED MUST
COMPLY WITH BS. 669 CURRENT EDITION.
L.P.G. FLEXIBLE CONNECTIONS MUST BE OF A
TYPE SUITABLE FOR L.P.G. AND CAPABLE OF
OPERATION UP TO 50 mbar AND TO CARRY A RED
STRIPE, BAND OR LABEL.

5. FITTING THE BATTERY

1.

The battery holder is located on the left hand side
of the front plinth.

2.

To gain access to the battery, open the main oven
door and lift up the battery holder lid.

3.

Fit the new battery ensuring positive (+) terminal is
next to the (+) sign on the battery holder. See Fig.4.

4.

Close the lid of the battery holder.

Z C G 6 2 0 0