Yamaha HUB User Manual

Page 27

Advertising
background image

27

Other Functions

NetworkAmp Manager—Owner’s Manual

New ACU16-C detected [ACU#xx]

ACU16-C gone offline [ACU#xx]

New NHB32-C detected [NHB#xx]

NHB32-C gone offline [NHB#xx]

Online/Offline Status events appear in blue in the Log window.

3 Power Switch Event

This type of event occurs when an amplifier is set to On or Standby.

Date, Time, LineKind, Device

For example:

01/Aug/2002, 21:30:25, PowerOn, [ACU#00 AMP#00]

In other words, amp #00, connected to ACU #00, was turned on at 21:30:25 on
01/Aug/2002.

The

LineKind

variable can be:

PowerOn

or

Standby

Power Switch events appear in blue in the Log window, as shown below.

4 Error Event

This type of event occurs when either a system error or parameter error occurs.

Date, Time, Error, ErrorMessage

For example:

01/Aug/2002, 21:30:25, Error, Duplicate Unit ID (NHB32-C:#00)

In other words, at 21:30:25 on 01/Aug/2002, it was detected that NHB #00 is set to the same
ID as another NHB32-C on the network.

The

ErrorMessage

variable can be any of the following:

Duplicate Unit ID [NHB#xx]

Duplicate Unit ID [ACU#xx]

Unit COM/MIDI Mode Conflict!

Too Many COM/MIDI Mode Units!

Unit EEPROM Access Error! [NHB#xx]

Unit EEPROM Access Error! [ACU#xx]

AES/EBU Input Sync Error [NHB#xx AES/EBUx CH1/2]

AES/EBU Input Sync Error [NHB#xx AES/EBUx CH3/4]

AES/EBU Input Sync Error [NHB#xx AES/EBUx CH5/6]

Advertising