Xantech HD44CC5 User Manual

Page 4

Advertising
background image

08905071B

-

4

-

RS232 COMMAND STRUCTURE


Where:

{CR#} – Carriage Return (0x0D)
{z#} - Zone Number. Range is 1..4 (1..16 if expanded)
{s#} - Source Input Number. Range is 1..4
{0/1} – Either 0 (zero) or 1 (one). 0 – Off, 1 – On.

NAME

COMMAND

RETURN

REMARKS

!{z#}PR01+

To turn on Zone 2: !2PR1+ or !02PR1+ or
!2PR01+ or !02PR01+

Zone Power

!{z#}PR00+

OK{CR}
ERROR{CR}

To turn off Zone1: !1PR0+ or !01PR0+ or
!1PR00+ or !01PR00+

Zone Power
Toggle

!{z#}PT+

OK{CR}
ERROR{CR}

All Zones Off

!EO+

OK{CR}
ERROR{CR}

Turns all the zones off.

All Zones On

!EA+

OK{CR}
ERROR{CR}

Turns all the zones on.

Zone Restore All

!RF+

OK{CR}
ERROR{CR}

Restore all the Zone-to-Source routing to the
current selection: !RF+

Input (Source)
Select

!{z#}SS{s#}+

OK{CR}
ERROR{CR}

To set Zone 1 to Source Input 4: !1SS4+

Ping Expansion
Port

!RP+

OK{CR}
ERROR{CR}

Request that any unit connected to the expansion
port respond with a ping.

Return Ping to
Xantech port

!SP+ +

Returns a +. Meant for inter-expansion box
communications.









Advertising