If the outlet spigot has not

been used before, remove

any blanking plug that

may be in place.

Push the drain hose onto

the spigot and secure with

a clip, ensure a loop is

formed in the drain hose

(see above) to prevent

waste from the sink enter-

ing the appliance.

If you intend to drain the hose from the machine into a

sink, make sure that the sink is empty and the plug hole

is not blocked. Use the plastic “U - Piece” supplied.

In the interest of the environment

The appliance should be connected to the FOUL drainage

system, the water will then be taken to a sewage works for

treatment before being discharged safely into a river.

It is essential that these appliances are not connected to

the surface water drainage system as this water is dis-

charged directly into a river or stream and may cause pol-

lution.

If you require any further advice please contact your local

water authority.

SHOWER

WASHING

MACHINE

DISHWASHER

BATH

SINK TOILET

BIDET

RAINWATER

‘RUN-OFF’

SURFACE WATER

DRAINS & SEWERS

UNTREATED

DISCHARGE

RIVER

RIVER

TREATED DISCHARGE

FOUL DRAIN

FOUL SEWERS

SEWAGE TREATMENT

WORKS

Electrical connection

Any electrical work required to install this appliance

should be carried out by a qualified electrician or compe-

tent person.

Warning! THIS APPLIANCE MUST BE EARTHED.

The manufacturer declines any liability should this

safety measure not be observed.

Before switching on, make sure the electricity supply

voltage is the same as that indicated on the appliance’s

rating plate.

Warning! Information on the electrical connection is

given on the rating plate on the inner edge of the

appliance door.
The appliance is supplied with a 13 amp plug fitted.

In the event of having to change the fuse in the plug sup-

plied, a 13 amp ASTA approved (BS1363/A) fuse must be

used.

Warning! A cut off plug inserted into a 13 amp

socket is a serious safety (shock) hazard.

Ensure that the cut off plug is disposed of safely. Should

the appliance power supply cable need to be replaced, this

MUST be carried out by our Service Force Centre. The

appliance should not be connected to the electrical supply

by means of an extension cable.
Note!

When the appliance is installed the power supply cable

must be accessible.

Building in

This appliance has been designed to be built into the

kitchen furniture. The recess should have the dimensions

shown in picture A.